Multiscale sensorless adaptive optics OCT angiography system for in vivo human retinal imaging
- 1 November 2017
- journal article
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 22 (12) , 1-10
Abstract
We present a multiscale sensorless adaptive optics (SAO) OCT system capable of imaging retinal structure and vasculature with various fields-of-view (FOV) and resolutions. Using a single deformable mirror and exploiting the polarization properties of light, the SAO-OCT-A was implemented in a compact and easy to operate system. With the ability to adjust the beam diameter at the pupil, retinal imaging was demonstrated at two different numerical apertures with the same system. The general morphological structure and retinal vasculature could be observed with a few tens of micrometer-scale lateral resolution with conventional OCT and OCT-A scanning protocols with a 1.7-mm-diameter beam incident at the pupil and a large FOV (15 deg× 15 deg). Changing the system to a higher numerical aperture with a 5.0-mm-diameter beam incident at the pupil and the SAO aberration correction, the FOV was reduced to 3 deg× 3 deg for fine detailed imaging of morphological structure and microvasculature such as the photoreceptor mosaic and capillaries. Multiscale functional SAO-OCT imaging was performed on four healthy subjects, demonstrating its functionality and potential for clinical utility.Keywords
Funding Information
- Michael Smith Health Research BC
- Alzheimer Society Research Program
- Natural Science and Engineering Research Council of Canada
- Canadian Institutes of Health Research
- Fondation Brain Canada
This publication has 47 references indexed in Scilit:
- NEW INSIGHTS INTO THE PATHOANATOMY OF DIABETIC MACULAR EDEMARetina, 2012
- New Directions in Ophthalmic Optical Coherence TomographyOptometry and Vision Science, 2012
- Reflective afocal broadband adaptive optics scanning ophthalmoscopeBiomedical Optics Express, 2011
- Adaptive optics and the eye (super resolution OCT)Eye, 2011
- Primary Open-Angle GlaucomaNew England Journal of Medicine, 2009
- Ultrahigh resolution optical coherence tomography and pancorrection for cellular imaging of the living human retinaOptics Express, 2008
- State-of-the-art retinal optical coherence tomographyProgress in Retinal and Eye Research, 2008
- Characteristics of the human isoplanatic patch and implications for adaptive optics retinal imagingJournal of Biomedical Optics, 2008
- Spectral analysis of spatial sampling by photoreceptors: Topological disorder prevents aliasingVision Research, 1982
- Radial peripapillary capillaries of the retina. I. Anatomy: human and comparative.British Journal of Ophthalmology, 1967