Telluric Effects on a Buried Pipeline
Author:
- 1 April 1993
- journal article
- Published by Association for Materials Protection and Performance (AMPP) in Corrosion
- Vol. 49 (4) , 343-350
Abstract
A 515-km pipeline in northeastern Australia exhibited 5 V telluric potential fluctuations in the 130 km of its length adjacent to the coast. The rest of the pipeline was relatively unaffected. The potential fluctuations were constrained using a combination of potentiostatic cathodic protection (CP) units, diodes connecting the pipeline to Earths, and insulating joints. There remained a significant rate of corrosion in the telluric-affected area. The CP criterion is to be modified and based on potentials that have been correlated with electrical-resistance probe data. This minimizes the effect of the variable soil voltage gradient errors in potential measurement resulting from the telluric effects and also the unknown effects of short duration positive transients. Additional work is required to determine acceptable transient potential frequencies, amplitudes and durations.Keywords
This publication has 1 reference indexed in Scilit:
- Induction of auroral zone electric currents within the Alaska pipelinePure and Applied Geophysics, 1978