Role of Seismic Isolation and Protection Devices in Enhancing Structural Resilience
Authors:
- Fariborz M. TehraniFTFariborz M. Tehrani
- Maryam NazariMNMaryam Nazari
- Ali NaghshinehANAli Naghshineh
- 8 April 2022
- book chapter
- Published by American Society of Civil Engineers (ASCE)
- p. 161-209
Abstract
Recent advances in the field of structural engineering have substantially shifted engineering paradigms in earthquake-resistant design. Key components of resilience, including robustness, resourcefulness, rapidity, and redundancy, interact with other structural characteristics, such as safety and reliability through performance-based design. This chapter details how seismic isolation enhances resilience in a practical way by isolating and protecting structures from transferred loads during earthquake events and/or damping the energy of transferred motions to structures during such events. Because of separation of friction and elastomeric-based mechanisms in EDF systems, sliding of the superstructure on top of the stainless-steel plate can function as a fuse, similar to pure-friction systems, to isolate the structure from severe ground motions. Applications of seismic isolation systems for protection of important structures, such as nuclear power plants, built near active faults are investigated.Keywords
This publication has 53 references indexed in Scilit:
- Seismic design and performance evaluation of steel-frame buildings designed using the 2005 National building code of CanadaCanadian Journal of Civil Engineering, 2009
- Multi-Storey Prestressed Timber Buildings in New ZealandStructural Engineering International, 2008
- Base isolation for near‐fault motionsEarthquake Engineering & Structural Dynamics, 2001
- Seismic response controlled structure with Active Variable Stiffness systemEarthquake Engineering & Structural Dynamics, 1993
- Performance analysis of aseismic base isolation systems for a multi-story buildingSoil Dynamics and Earthquake Engineering, 1991
- Multi-story base-isolated buildings under a harmonic ground motion — Part II: Sensitivity analysisNuclear Engineering and Design, 1990
- Multi-story base-isolated buildings under a harmonic ground motion — Part I: A comparison of performances of various systemsNuclear Engineering and Design, 1990
- A comparative study of performances of various base isolation systems, part II: Sensitivity analysisEarthquake Engineering & Structural Dynamics, 1990
- A comparative study of performances of various base isolation systems, part I: Shear beam structuresEarthquake Engineering & Structural Dynamics, 1989
- Vibration control of structures under earthquake loading by three‐stage friction‐grip elementsEarthquake Engineering & Structural Dynamics, 1988