Effects of Stent Design and Atherosclerotic Plaque Composition on Arterial Wall Biomechanics
- 1 December 2008
- journal article
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 15 (6) , 643-654
Abstract
Purpose: To examine the solid mechanical effects of varying stent design and atherosclerotic plaque stiffness on the biomechanical environment induced in a diseased artery wall model. Methods: Computational modeling techniques were employed to investigate the final radius of the lumen and artery wall stresses after stent implantation. Two stent designs were studied (one stiff and one less stiff). The stenotic artery was modeled as an axisymmetrical diseased vessel with a 20% stenosis by diameter. The material properties of the diseased tissue in the artery models varied. Atherosclerotic plaques half as stiff (0.5×), of equal stiffness (1.0×), or twice as stiff (2.0×) as the artery wall were investigated. Results: Final lumen radius was dependent on stent design, and the stiffer stent deformed the artery to an approximately 10% greater radius than the more compliant design. Alternatively, circumferential stress levels were dependent on both stent design and plaque material properties. Overall, the stiffer stent subjected the artery wall to much higher stress values than the more compliant design, with differences in peak values of 0.50, 0.31, and 0.09 MPa for the 2.0×, 1.0×, and 0.5× stiff plaques, respectively. Conclusion: Evidence suggests that a judicious choice of stent design can minimize stress while maintaining a patent lumen in stenotic arteries. If confronted with a rigid, calcified plaque, stent design is more important, as design differences can impose dramatically different stress fields, while still providing arterial patency. Alternatively, stent design is not as much of an issue when treating a soft, lipid-laden plaque, as stress fields do not vary significantly among stent designs.Keywords
This publication has 30 references indexed in Scilit:
- A Numerical Model to Study the Interaction of Vascular Stents with Human Atherosclerotic LesionsAnnals of Biomedical Engineering, 2007
- Modeling Plaque Fissuring and Dissection during Balloon Angioplasty InterventionAnnals of Biomedical Engineering, 2007
- Stented Artery Flow Patterns and Their Effects on the Artery WallAnnual Review of Fluid Mechanics, 2007
- Coronary-Artery StentsNew England Journal of Medicine, 2006
- Cardiovascular stent design and vessel stresses: a finite element analysisJournal of Biomechanics, 2005
- Reporting Standards for Carotid Artery Angioplasty and Stent PlacementStroke, 2004
- Stainless and shape memory alloy coronary stents: a computational study on the interaction with the vascular wallBiomechanics and Modeling in Mechanobiology, 2004
- Pathobiologic Responses to Stenting 11Supported in part by grants from the National Institutes of Health (GM/HL49039 and HL03104), the Burroughs Wellcome Fund for Experimental Therapeutics, Durham, North Carolina, and the Whitaker Foundation, Rosslyn, Virginia.The American Journal of Cardiology, 1998
- Experimental Approaches on Measuring the Mechanical Properties and Constitutive Laws of Arterial WallsJournal of Biomechanical Engineering, 1993
- Vessel, plaque, and lumen morphology after transluminal balloon angioplasty. Quantitative study in distended human arteries.Arteriosclerosis: An Official Journal of the American Heart Association, Inc., 1987