Rate of Strabismus Detection on Digital Photographs Increases by Using Off-center Near Target
Authors:
- Ron MaorRMRon Maor
- Joanna HollandJHJoanna Holland
- Vijay TailorVijay Tailor
- Marina BantekaMBMarina Banteka
- Payal KhandelwalPKPayal Khandelwal
- Selina GlazeSGSelina Glaze
- Simon BarnardSBSimon Barnard
- Yuval YashivYYYuval Yashiv
- Annegret H. Dahlmann-NoorADAnnegret H. Dahlmann-Noor
- 1 March 2017
- journal article
- Published by SLACK, Inc. in Journal of Pediatric Ophthalmology & Strabismus
- Vol. 54 (2) , 90-96
Abstract
Purpose: To increase the detection rate of strabismus on digital photographs, with the ultimate aim of developing a new automated strabismus detection algorithm. Methods: In this prospective case series, the authors acquired digital face photographs of 409 children with manifest or latent strabismus, using a 14-million–pixel camera with CCD image sensor. Of the last 52 enrolled, 34 image sets were selected for this study: 29 with manifest and 5 with latent strabismus. Images were taken at a distance of 40 to 70 cm in primary position, with the camera lens as the fixation target and in slight off-center fixation, and using a novel target of small light-emitting diodes mounted onto the camera case. The location of the corneal light reflection was manually calculated in relation to the center of the pupil in both eyes and ocular deviation as the difference in corneal light reflection location between the two eyes. In orthotropia, the expected deviation is zero. Results: In children with phorias, the mean corneal light reflection location difference between the eyes was −0.10 ± 0.14 mm in primary position and −2.02 ± 0.39 mm in off-center fixation. Using a threshold of ±0.5 mm on either side of zero for central and of 2 mm for off-center fixation, sensitivity to detect strabismus increased from 65.6% in central to 79.3% in off-center fixation, respectively. The calculation of specificity will require inclusion of a population of individuals without strabismus. Conclusions: Off-center fixation onto a near target ensures that participants are actively looking at the target and may increase accommodative effort, thereby increasing the detection rate of strabismus.Keywords
This publication has 10 references indexed in Scilit:
- Development and Validation of a Smartphone-Based Visual Acuity Test (Peek Acuity) for Clinical Practice and Community-Based FieldworkJAMA Ophthalmology, 2015
- Computational methodology for automatic detection of strabismus in digital images through Hirschberg testComputers in Biology and Medicine, 2012
- Assessment of binocular alignment using the three-dimensional Strabismus Photo AnalyzerBritish Journal of Ophthalmology, 2011
- Diagnosis and Management of Strabismus Using TelemedicineTelemedicine and e-Health, 2008
- Does Assessing Eye Alignment along with Refractive Error or Visual Acuity Increase Sensitivity for Detection of Strabismus in Preschool Vision Screening?Investigative Ophthalmology & Visual Science, 2007
- The role of telemedicine in the assessment of strabismusJournal of Telemedicine and Telecare, 2002
- Strabismus examination by telemedicine15The authors have no proprietary interest in any of the devices described in the manuscript.Ophthalmology, 2000
- Photographic Method for Bruckner and Hirschberg TestingOptometry and Vision Science, 1989
- The Hirschberg TestOptometry and Vision Science, 1988
- Axial Length and the Hischberg TestOptometry and Vision Science, 1978