Failed radial head arthroplasty treated by removal of the implant
- 1 November 2024
- journal article
- research article
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 106-B (11) , 1327-1332
Abstract
Aims: In patients with a failed radial head arthroplasty (RHA), simple removal of the implant is an option. However, there is little information in the literature about the outcome of this procedure. The aim of this study was to review the mid-term clinical and radiological results, and the rate of complications and removal of the implant, in patients whose initial RHA was undertaken acutely for trauma involving the elbow.Methods: A total of 11 patients in whom removal of a RHA without reimplantation was undertaken as a revision procedure were reviewed at a mean follow-up of 8.4 years (6 to 11). The range of motion (ROM) and stability of the elbow were recorded. Pain was assessed using a visual analogue scale (VAS). The functional outcome was assessed using the Mayo Elbow Performance Score (MEPS), the Oxford Elbow Score (OES), and the Disabilities of the Arm, Shoulder and Hand questionnaire (DASH). Radiological examination included the assessment of heterotopic ossification (HO), implant loosening, capitellar erosion, overlengthening, and osteoarthritis. Complications and the rate of further surgery were also recorded.Results: The indications for removal of the implant were stiffness in five patients, aseptic loosening in five, and pain attributed to the RHA in three. The mean time interval between RHA for trauma to removal was ten months (7 to 21). Preoperatively, three patients had overlengthening of the implant, three had capitellar erosion, six had HO, and four had radiological evidence of loosening. At the final follow-up, the mean the flexion-extension arc improved significantly by 38.2° (95% CI 20 to 59; p = 0.002) and the mean arc of prono-supination improved significantly by 20° (95% CI 0 to 72.5; p = 0.035). The mean pain VAS score improved significantly by 3.5 (95% CI 2 to 5.5; p = 0.004). The mean MEPS improved significantly by 27.5 (95% CI 17.5 to 42.5; p = 0.002). The mean OES improved significantly by 9 (95% CI 2.5 to 14; p = 0.012), and the mean DASH score improved significantly by 23.5 (95% CI 7.5 to 31.6; p = 0.012). Ten patients (91%) had HO and osteoarthritis. Two patients underwent further surgery due to stiffness and pain, respectively.Conclusion: Simple removal of the implant at revision surgery following a failed RHA introduced following trauma provides satisfactory mid-term results with an acceptable risk of complications. Osteoarthritis, instability, and radioulnar impingement were not problems in this series.Cite this article: Bone Joint J 2024;106-B(11):1327–1332.Keywords
This publication has 37 references indexed in Scilit:
- Overlengthening of the radial column in radial head replacement: a review of the literature and presentation of a classification systemArchives of orthopaedic and trauma surgery, 2020
- The Rate of Radial Head Prosthesis Removal or Revision: A Systematic Review and Meta-AnalysisThe Journal of Hand Surgery, 2018
- Comparison between radial head arthroplasty and open reduction and internal fixation in patients with radial head fractures (modified Mason type III and IV): a meta-analysisEuropean Journal of Orthopaedic Surgery & Traumatology, 2016
- Radial head prosthesis in complex elbow dislocations: effect of oversizing and comparison with ORIFInternational Orthopaedics, 2014
- Surgical treatment of elbow stiffness caused by post-traumatic heterotopic ossificationJournal of Shoulder and Elbow Surgery, 2013
- Radial head fracture: open reduction–internal fixation or prosthetic replacementJournal of Shoulder and Elbow Surgery, 2011
- Radial head prosthesis after fracture of radial head with associated elbow instabilityArchives of orthopaedic and trauma surgery, 2006
- Development of an upper extremity outcome measure: The DASH (disabilities of the arm, shoulder, and head)American Journal of Industrial Medicine, 1996
- Valgus stability of the elbowJournal of Orthopaedic Research, 1987
- Some observations on fractures of the head of the radius with a review of one hundred casesBritish Journal of Surgery, 1954