Comparison of Intraocular Pressure Measurements Obtained by Icare PRO Rebound Tonometer, Tomey FT-1000 Noncontact Tonometer, and Goldmann Applanation Tonometer in Healthy Subjects
Authors:
- Şemsettin BilakŞBŞemsettin Bilak
- Burak BilginBBBurak Bilgin
- Ali ŞimşekAŞAli Şimşek
- Musa ÇapkinMÇMusa Çapkin
- Ali Hakim ReyhanARAli Hakim Reyhan
- 1 January 2015
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 24 (8) , 613-618
Abstract
To compare intraocular pressure (IOP) measurements obtained by Icare PRO rebound tonometer (RT), Tomey FT-1000 noncontact tonometer (NCT), and Goldmann applanation tonometer (GAT) in healthy subjects, and to investigate the influence of central corneal thickness (CCT) on IOP measurements. A total of 132 eyes of 66 healthy subjects were included in the study. All IOP measurements were applied in a sitting position and always in the same order (RT, NCT, and GAT). CCT was measured by noncontact anterior segment optical coherence tomography. The mean CCT was 523.5±31.2 μm. The mean IOPs with GAT, NCT, and RT measurements were 14.56±2.77, 13.42±2.99, 14.18±2.55 mm Hg, respectively. A significantly good agreement was found between RT and GAT measurements (P=0.515). The mean difference between RT and GAT measurements was -0.38 mm Hg. An underestimation was found in NCT measurements compared with GAT ones as defined from paired comparisons (P=0.003). The mean difference between NCT and GAT measurements was -1.14 mm Hg. There was no significant difference between NCT and RT readings (P=0.069). The mean difference between NCT and RT measurements was -0.76 mm Hg. There was a significant correlation between GAT-NCT (r=0.740, P<0.001), GAT-RT (r=0.743, P<0.001), NCT-RT (r=0.729, P<0.001) measurement methods. The increment in measured IOP for a 10 μm increase in CCT was 0.16, 0.33, and 0.18 mm Hg for the GAT, NCT, and RT, respectively. The IOP readings with the new Icare PRO RT showed good correlation with those obtained by GAT. Tomey FT-1000 NCT underestimated the IOP compared with GAT.Keywords
This publication has 29 references indexed in Scilit:
- Goldmann applanation tonometry compared with corneal-compensated intraocular pressure in the evaluation of primary open-angle GlaucomaBMC Ophthalmology, 2012
- Evaluation of the Icare-ONE rebound tonometer as a self-measuring intraocular pressure device in normal subjectsGraefe's Archive for Clinical and Experimental Ophthalmology, 2012
- Comparison of intraocular pressure measurement between rebound, non‐contact and Goldmann applanation tonometry in treated glaucoma patientsClinical & Experimental Ophthalmology, 2011
- A History of Intraocular Pressure and Its MeasurementOptometry and Vision Science, 2011
- Application of the ICare Rebound Tonometer in Healthy InfantsJournal of Glaucoma, 2011
- Repeatability of intra-ocular pressure and central corneal thickness measurements provided by a non-contact method of tonometry and pachymetryGraefe's Archive for Clinical and Experimental Ophthalmology, 2010
- Intraocular pressure measurement and goldmann calibration. An eye opening review of practice in United KingdomEye, 2007
- Assessment of the accuracy and reliability of the Topcon CT80 non‐contact tonometerClinical and Experimental Optometry, 2006
- Accuracy of the New ICare Rebound Tonometer vs. Other Portable Tonometers in Healthy EyesOptometry and Vision Science, 2006
- Corneal thickness in glaucoma screening, diagnosis, and managementCurrent Opinion in Ophthalmology, 2004