Accuracy of CT hounsfield units for predicting cage subsidence and pedicle screw loosening after lumbar interbody fusion: a systematic review and meta-analysis
- 15 August 2025
- journal article
- review article
- Published by Springer Nature in Neurosurgical Review
- Vol. 48 (1) , 602
Abstract
Cage subsidence (CS) and pedicle screw loosening (PSL) are significant postoperative complications following lumbar interbody fusion (LIF) surgeries, often associated with poor bone quality. Hounsfield Unit (HU) measurements from preoperative CT scans have emerged as a potential non-invasive predictor of bone density. This study aims to evaluate the diagnostic accuracy of HU in predicting CS and PSL. A systematic review and meta-analysis were conducted according to PRISMA guidelines. Databases searched included PubMed, Europe PMC, ScienceDirect, and Google Scholar. Studies with irrelevant outcomes, review articles, case reports, case series, animal studies, cadaveric studies, and abstract only articles were excluded. Pooled estimates of standardized mean difference (SMD), sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) were calculated using a random-effects model. Risk of bias was assessed using QUADAS-2, and the GRADE framework was used to evaluate evidence quality. Seventeen retrospective cohort studies involving 2,294 patients were included. HU values were significantly lower in patients with complications. For CS, the pooled SMD was - 37.43 [95% CI: -44.80 to -30.08], and for PSL, -24.55 [95% CI: -29.04 to -20.06]. The pooled sensitivity and specificity of HU for predicting CS were 0.83 [95% CI: 0.71-0.90] and 0.86 [95% CI: 0.75-0.93], with an AUC of 0.91. For PSL, the pooled sensitivity and specificity were 0.80 [95% CI: 0.72-0.86] and 0.68 [95% CI: 0.56-0.78], with an AUC of 0.81. GRADE assessment rated the evidence as moderate quality. HU values are reliable predictors of CS and PSL after LIF, with stronger accuracy for CS, that may serve as a practical tool in preoperative planning to identify high-risk patients and reduce complication rates. However, the retrospective nature and methodological variability among included studies may affect generalizability, that warrants for further large scale, prospective studies.Keywords
This publication has 46 references indexed in Scilit:
- Osteoporosis in spine surgery patients: what is the best way to diagnose osteoporosis in this population?Neurosurgical Focus, 2020
- The association between lower Hounsfield units on computed tomography and cage subsidence after lateral lumbar interbody fusionNeurosurgical Focus, 2020
- Risk Factors of Cage Subsidence in Patients Received Minimally Invasive Transforaminal Lumbar Interbody FusionSpine, 2020
- Computed tomography Hounsfield unit–based prediction of pedicle screw loosening after surgery for degenerative lumbar spine diseaseJournal of Neurosurgery: Spine, 2020
- Measurement Techniques and Utility of Hounsfield Unit Values for Assessment of Bone Quality Prior to Spinal InstrumentationSpine, 2019
- Pedicle screw loosening: the value of radiological imagings and the identification of risk factors assessed by extraction torque during screw removal surgeryJournal of Orthopaedic Surgery and Research, 2019
- Hounsfield unit of screw trajectory as a predictor of pedicle screw loosening after single level lumbar interbody fusionJournal of Orthopaedic Science, 2018
- Lumbar interbody fusion: techniques, indications and comparison of interbody fusion options including PLIF, TLIF, MI-TLIF, OLIF/ATP, LLIF and ALIF2015
- QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy StudiesAnnals of Internal Medicine, 2011
- Hounsfield Units for Assessing Bone Mineral Density and Strength: A Tool for Osteoporosis ManagementJournal of Bone and Joint Surgery, 2011