Dual energy imaging using a clinical on-board imaging system
Authors:
- M A HoggarthMHM A Hoggarth
- J LuceJLJ Luce
- F SyedaFSF Syeda
- T S BrayTBT S Bray
- A BlockABA Block
- S NagdaSNS Nagda
- J C RoeskeJRJ C Roeske
- 4 June 2013
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 58 (12) , 4331-4340
Abstract
Dual energy (DE) imaging consists of obtaining kilovoltage (kV) x-ray images at two different diagnostic energies and performing a weighted subtraction of these images. A third image is then produced that highlights soft tissue. DE imaging has been used by radiologists to aid in the detection of lung malignancies. However, it has not been used clinically in radiotherapy. The goal of this study is to assess the feasibility of performing DE imaging using a commercial on-board imaging system. Both a simple and an anthropomorphic phantom were constructed for this analysis. Planar kV images of the phantoms were obtained using varied imaging energies and mAs. Software was written to perform DE subtraction using empirically determined weighting factors. Tumor detectability was assessed quantitatively using the signal-difference-to-noise ratio (SDNR). Overall DE subtraction suppressed high density objects in both phantoms. The optimal imaging technique, providing the largest SDNR with a dose less than our reference technique was 140 kVp, 1.0 mAs and 60 kVp, 3.2 mAs. Based on this analysis, DE subtraction imaging is feasible using a commercial on-board imaging system and may improve the visualization of tumors in lung cancer patients undergoing image-guided radiotherapy.Keywords
This publication has 18 references indexed in Scilit:
- Dual-Energy CT with Single- and Dual-Source Scanners: Current Applications in Evaluating the Genitourinary TractRadioGraphics, 2012
- Virtual Monochromatic Spectral Imaging with Fast Kilovoltage Switching: Improved Image Quality as Compared with That Obtained with Conventional 120-kVp CTRadiology, 2011
- Dual Energy Subtraction and Temporal Subtraction Chest RadiographyJournal of Thoracic Imaging, 2008
- Recent Advances in Chest RadiographyRadiology, 2006
- Dual Energy Subtraction Digital RadiographyJournal of Thoracic Imaging, 2006
- Temporal subtraction of dual-energy chest radiographsMedical Physics, 2006
- AAPM protocol for 40–300 kV x‐ray beam dosimetry in radiotherapy and radiobiologyMedical Physics, 2001
- A correlated noise reduction algorithm for dual‐energy digital subtraction angiographyMedical Physics, 1989
- Comparison of Dual-Energy and Conventional Chest Radiography for Nodule DetectionInvestigative Radiology, 1989
- A method for selective tissue and bone visualization using dual energy scanned projection radiographyMedical Physics, 1981