Abstract
Partial discharge (PD) is a localized insulation failure that occurs without completely bridging the electrodes. While PD in sinusoidal excitations has been extensively studied with conventional detection and analysis methods, wide bandgap (WBG)-based electric drives introduce new challenges due to their high-frequency and high-speed switching. These features give rise to non-uniform voltage and charge distributions, along with voltage overshoot and ringing, governed by a geometry of PD object and drive parameters such as switching frequency and slew rate. Moreover, these fast-switching transients complicate PD detection due to electromagnetic interference (EMI). This paper reviews PD characteristics in WBG-based drives, highlighting the challenges in WBG-based drives. The review explores opportunities to improve PD location prediction through voltage distribution analysis based on the impedance of PD objects, as well as to optimize insulation design by considering charge distribution and methods for reducing the electric field across the insulation. Furthermore, it discusses methods to improve the signal-to-noise ratio (SNR) of PD detection, including a reduction of common-mode voltage (CMV) and current with active EMI filters, thereby enhancing detection reliability in WBG-based electric drives.

This publication has 58 references indexed in Scilit: