Risk factors of thigh pain following total hip arthroplasty with short, tapered-wedge stem
Authors:
- 7 August 2020
- journal article
- research article
- Published by Springer Nature in International Orthopaedics
- Vol. 44 (12) , 2553-2558
Abstract
Purpose The occurrence of thigh pain following cementless total hip arthroplasty (THA) may be dependent on multiple factors, which may differ with design of the prosthesis. Thus, this study aimed to investigate the frequency of thigh pain following cementless THA using a short, tapered-wedge stem to identify risk factors for thigh pain. Methods This retrospective cohort study analysed 222 joints of patients who underwent THA with a short, tapered-wedge stem. Thigh pain was evaluated using a questionnaire during each follow-up visit, and the clinical and radiographic assessments were compared. Results Thigh pain occurred in 37 patients (16.7%) during the follow-up period. The pain started two to 24 months after THA. Multivariate analysis demonstrated that higher University of California, Los Angeles, activity rating (odds ratio 7.2; 95% confidence interval (CI) 3.0–17.2); Dorr type C femoral bone shape (odds ratio 1.5; 95% CI 1.1–2.0); and stem tip-cortical bone contact (odds ratio 8.2; 95% CI 2.3–29.4) were significant risk factors of thigh pain following THA. Post-operatively, cortical hypertrophy at Gruen zone 4 was significantly found in patients with thigh pain (p value = 0.032). Conclusion Risk factors of pain following THA with short, tapered-wedge stem were high activity level, Dorr type C femoral bone shape, and stem tip contacting the distal bone surface. Moreover, post-operative cortical hypertrophy at the distal stem tip significantly increased the incidence of thigh pain. Therefore, we must pay attention to the aforementioned factors to avoid post-operative thigh pain when using a short, tapered-wedge stem.Keywords
This publication has 27 references indexed in Scilit:
- Incidence and Location of Pain in Young, Active Patients Following Hip ArthroplastyThe Journal of Arthroplasty, 2015
- Primary stability of the Fitmore® stem: biomechanical comparisonInternational Orthopaedics, 2013
- Hip arthroplastyThe Lancet, 2012
- Modern Proximally Tapered Uncemented Stems Can Be Safely Used in Dorr Type C Femoral BoneThe Journal of Arthroplasty, 2012
- Over 25 years survival after Charnley’s total hip arthroplastyInternational Orthopaedics, 2011
- Survival of the Cementless Spotorno® Stem in the Second DecadeClinical Orthopaedics and Related Research, 2009
- Chronic pain following total hip arthroplasty: a nationwide questionnaire studyActa Anaesthesiologica Scandinavica, 2006
- Patients' perception of pain after total hip arthroplastyThe Journal of Arthroplasty, 2000
- Total hip replacement using APR systemTechniques in Orthopaedics, 1986
- "Modes of Failure" of Cemented Stem-type Femoral ComponentsClinical Orthopaedics and Related Research, 1979