Compliant vascular models 3D printed with the Stratasys J750: a direct characterization of model distensibility using intravascular ultrasound
Open Access
- 3 September 2021
- journal article
- research article
- Published by Springer Nature in 3D Printing in Medicine
- Vol. 7 (1) , 1-11
Abstract
Purpose: The purpose of this study is to evaluate biomechanical accuracy of 3D printed anatomical vessels using a material jetting printer (J750, Stratasys, Rehovot, Israel) by measuring distensibility via intravascular ultrasound. Materials and methods: The test samples are 3D printed tubes to simulate arterial vessels (aorta, carotid artery, and coronary artery). Each vessel type is defined by design geometry of the vessel inner diameter and wall thickness. Vessel inner diameters are aorta = 30mm, carotid = 7mm, and coronary = 3mm. Vessel wall thickness are aorta = 3mm, carotid = 1.5mm, and coronary = 1mm. Each vessel type was printed in 3 different material options. Material options are user-selected from the J750 printer software graphical user interface as blood vessel wall anatomy elements in ‘compliant’, ‘slightly compliant’, and ‘rigid’ options. Three replicates of each vessel type were printed in each of the three selected material options, for a total of 27 models. The vessels were connected to a flow loop system where pressure was monitored via a pressure wire and cross-sectional area was measured with intravascular ultrasound (IVUS). Distensibility was calculated by comparing the % difference in cross-sectional area vs. pulse pressure to clinical literature values. Target clinical ranges for normal and diseased population distensibility are 10.3-44 % for the aorta, 5.1-10.1 % for carotid artery, and 0.5-6 % for coronary artery. Results: Aorta test vessels had the most clinically representative distensibility when printed in user-selected ‘compliant’ and ‘slightly compliant’ material. All aorta test vessels of ‘compliant’ material (n = 3) and 2 of 3 ‘slightly compliant’ vessels evaluated were within target range. Carotid vessels were most clinically represented in distensibility when printed in ‘compliant’ and ‘slightly compliant’ material. For carotid test vessels, 2 of 3 ‘compliant’ material samples and 1 of 3 ‘slightly compliant’ material samples were within target range. Coronary arteries were most clinically represented in distensibility when printed in ‘slightly compliant’ and ‘rigid’ material. For coronary test vessels, 1 of 3 ‘slightly compliant’ materials and 3 of 3 ‘rigid’ material samples fell within target range. Conclusions: This study suggests that advancements in materials and 3D printing technology introduced with the J750 Digital Anatomy 3D Printer can enable anatomical models with clinically relevant distensibility.Keywords
Funding Information
- Jacobs Institute and the New York Empire State Development Grant (Jacobs Institute and the New York Empire State Development Grant)
This publication has 28 references indexed in Scilit:
- Three‐dimensional printing of MRI‐visible phantoms and MR image‐guided therapy simulationMagnetic Resonance in Medicine, 2016
- Treatment planning for image-guided neuro-vascular interventions using patient-specific 3D printed phantomsProceedings of SPIE, 2015
- Towards real-time 3D ultrasound planning and personalized 3D printing for breast HDR brachytherapy treatmentRadiotherapy and Oncology, 2015
- Challenges and limitations of patient-specific vascular phantom fabrication using 3D Polyjet printingProceedings of SPIE, 2014
- Preoperative Simulations of Endovascular Treatment for a Cerebral Aneurysm Using a Patient-Specific Vascular Silicone ModelNeurologia medico-chirurgica, 2013
- Uncomplicated obesity is associated with abnormal aortic function assessed by cardiovascular magnetic resonanceJournal of Cardiovascular Magnetic Resonance, 2008
- Arterial Distensibility in AdolescentsCirculation, 2005
- Determinants of coronary artery compliance in subjects with and without angiographic coronary artery diseaseJACC, 2002
- Carotid artery distensibility and distending pressure in hypertensive humans.Hypertension, 1994
- Determinants of coronary compliance in patients with coronary artery disease: An intravascular ultrasound studyJACC, 1994