Influence of Voltage Deviation and Asymmetry on Transitional Processes in Asynchronous Electric Drive

Authors:

Abstract
Investigations of electromagnetic and electromechanical transients in an asynchronous electric drive with voltage deviation and asymmetry have been carried out. Analytical expressions are obtained that describe the transients in an asynchronous electric drive with a shock load at voltage deviation and asymmetry.As the voltage decreases and asymmetries, the electromechanical constant of time increases, and as the voltage increases, electromechanical constant decreases. As a result, in drives with a small electromechanical time constant, increasing the voltage can cause torques and speed to fluctuate, while reducing and asymmetry can eliminate them.In electric drives with a large moment of inertia, the transient process is aperiodic. When the voltage is higher than the nominal one, the duration of the transient process decreases, and when the voltage decreases and asymmetries, duration of the transient process increases.The decrease and asymmetry of the voltage causes a decrease in the steady angular speed compared to the nominal, and an increase in voltage - angular speed increase.

This publication has 7 references indexed in Scilit: