Extraction of Vital Sign Based on Improved Complete Ensemble Empirical Mode Decomposition with Adaptive Noise for UWB radar

Authors:

Abstract
In life search and rescue based on UWB radar, life signals are easy to be submerged by clutter and difficult to extract. To solve this problem, a UWB radar vital signs extraction method based on ICEEMDAN is proposed. The complexity of slow time series is calculated by PE, and the distance gate with strong vital signs is selected. Then, the selected slow time series is reconstructed and denoised by ICEEMDAN, and the frequency of the reconstructed signals is extracted by FFT. The results show that the average respiratory frequency error is 0.0127 Hz and the average heartbeat frequency error is 0.036Hz. The algorithm proposed in this paper can accurately extract the respiratory and heart rates.

This publication has 7 references indexed in Scilit: