Does the additional application of a polylactide film (SurgiWrap) to a lightweight mesh (TiMesh) reduce adhesions after laparoscopic intraperitoneal implantation procedures? Experimental results obtained with the laparoscopic porcine model
- 24 April 2008
- journal article
- Published by Springer Nature in Surgical Endoscopy
- Vol. 22 (11) , 2433-2439
Abstract
Intraperitoneal repair of incisional hernias using a mesh makes particular demands on the material used. In addition to good integration of the mesh on the parietal side, adhesions to the visceral peritoneum must be avoided. Large-pore, light-weight meshes induce fewer adhesions than heavy-weight polypropylene meshes. Although numerous adhesion-barrier substances for use in combination with a polypropylene mesh have been tested already, mostly in open small animal models, unequivocal benefits have been identified to date in only a few of the experiments. Using the laparoscopic intraperitoneal onlay mesh technique, six pigs were implanted with either a lightweight polypropylene mesh (TiMesh light) or TiMesh plus an adhesion-barrier film made of polylactide (SurgiWrap). After 3 months, the animals underwent a postmortem laparoscopy, and specimens were obtained for planimetric and histologic investigations. No adhesions to intestinal structures were found in any of the animals. Adhesions between the greater omentum and the mesh did not differ significantly between the TiMesh (32%) and SurgiWrap (33.5%) groups. The shrinkage of the mesh’s surface area was comparable between the two groups (18% vs. 21%). Histology showed pronounced inflammatory reaction and bridging of scar tissue between the filaments with the use of SurgiWrap versus TiMesh light without film. However, immunohistochemical investigations examining the partial volume of the inflammatory cells, the proliferation marker Ki67, and the apoptotic index at the interface of the filaments all failed to show any significant differences. To avoid adhesions, it is essential that the acute and chronic inflammatory reaction to the implanted material be as small as possible. This requirement is met specifically by the lightweight polypropylene mesh TiMesh light. The additional application of a slowly absorbable adhesion-barrier film made of polylactide (SurgiWrap) does not appear to confer any further benefit.Keywords
This publication has 28 references indexed in Scilit:
- Polypropylene in the intra-abdominal position: Influence of pore size and surface areaHernia, 2004
- Fewer adhesions induced by laparoscopic surgery?Surgical Endoscopy, 2004
- Prevention of adhesions to polypropylene mesh1Journal of the American College of Surgeons, 2004
- Prevention of adhesion formation to polypropylene mesh by collagen coating: A randomized controlled study in a rat model of ventral hernia repairSurgical Endoscopy, 2004
- Resistance to adhesion formation: A comparative study of treated and untreated mesh products placed in the abdominal cavityHernia, 2004
- In vivo studies comparing the biocompatibility of various polypropylene meshes and their handling properties during endoscopic total extraperitoneal (TEP) patchplasty: an experimental study in pigsSurgical Endoscopy, 2004
- Persistent Extracellular Matrix Remodelling at the Interface to Polymers Used for Hernia RepairEuropean Surgical Research, 2003
- Prevention of Adhesion to Prosthetic MeshAnnals of Surgery, 2003
- The influence of differing pore sizes on the biocompatibility of two polypropylene meshes in the repair of abdominal defectsHernia, 2001
- The effect of phagocytosis of poly(L‐lactic acid) fragments on cellular morphology and viabilityJournal of Biomedical Materials Research, 1993