Combined LIBS and Raman spectroscopy: an approach for salinity detection in the field of seawater investigation
Authors:
- 24 February 2022
- journal article
- research article
- Published by Optica Publishing Group in Applied Optics
- Vol. 61 (7) , 1718-1725
Abstract
As salinity is an important indicator in marine geology, ecology, breeding, and other fields, accurate, rapid, and continuous measurement of salinity is of great significance in marine investigations. At present, the seawater salinity detection methods used in practice are mainly based on the principle that the conductivity and refractive index parameters of the water change with the concentration of elements, which are composed of salinity change. However, these methods quantitatively analyze salinity values by measuring other parameters (electrical or optical parameters) that may change depending on the salinity of the water, rather than the mass fraction of the components that make up the salinity. Moreover, when the salinity value of seawater water changes substantially or the proportion of various common components composing salinity changes significantly, the detection accuracy of the above methods is difficult to guarantee. Therefore, a spectral approach, LIBS, and the Raman spectroscopy combination method for salinity analyzation, LRSS, were proposed to provide a new option. The main idea of this approach is to use the two spectral detection methods, LIBS and Raman, to determine the mole values of cations and non-monatomic anions in per unit quality (1 kg) of water, respectively. Then the mole value of the chloride ion, which is the main monatomic anion in seawater, can be determined according to the electrically neutral principle. Based on all the obtained molar values and the molar mass of each ion, the salinity of the water sample can be determined. To demonstrate the performance of this new method, we compared it with LIBS under laboratory conditions and found that, when non-monatomic anions are present in the water, the accuracy of LRSS is significantly improved compared to using the LIBS method alone. Moreover, we also compared the LRSS with the other two traditional methods through the 11 water samples configured and found that the absolute value relative error of the LRSS is only 2.63% when the salinity and components concentration change is in the possible range, which is better than the conductivity method 0.53 times and better than the refractive index method 1.52 times.Keywords
Funding Information
- Natural Science Foundation of Shandong Province (ZR201910290171, ZR2019MD016)
- National Key Research and Development Program of China (2016YFC0302101)
- National Natural Science Foundation of China (41976173)
This publication has 35 references indexed in Scilit:
- Investigation of laser-induced breakdown spectroscopy of a liquid jetApplied Optics, 2010
- The composition of Standard Seawater and the definition of the Reference-Composition Salinity ScaleDeep Sea Research Part I: Oceanographic Research Papers, 2008
- In situ Raman analyses of deep‐sea hydrothermal and cold seep systems (Gorda Ridge and Hydrate Ridge)Geochemistry, Geophysics, Geosystems, 2006
- Dual-Pulse LIBS Using a Pre-Ablation Spark for Enhanced Ablation and EmissionApplied Spectroscopy, 2000
- Determination of Seawater Salinity by Ultraviolet Spectroscopic MeasurementsApplied Spectroscopy, 1997
- Laser-induced breakdown in aqueous mediaProgress in Quantum Electronics, 1997
- The shallow salinity minima of the Pacific OceanDeep Sea Research and Oceanographic Abstracts, 1973
- Measurements of the refractive index of sea water relative to copenhagen standard sea waterDeep Sea Research and Oceanographic Abstracts, 1967
- The electrical conductivity/chlorinity relationship in natural sea waterDeep Sea Research and Oceanographic Abstracts, 1967
- The bromide/chlorinity and sulphate/chlorinity ratio in sea waterDeep Sea Research and Oceanographic Abstracts, 1966