Continuous monitoring is superior to manual measurements in detecting vital sign deviations in patients with COVID‐19
Open Access
- 11 March 2023
- journal article
- research article
- Published by Wiley in Acta Anaesthesiologica Scandinavica
- Vol. 67 (5) , 640-648
Abstract
Background: Patients admitted to the emergency care setting with COVID‐19‐infection can suffer from sudden clinical deterioration, but the extent of deviating vital signs in this group is still unclear. Wireless technology monitors patient vital signs continuously and might detect deviations earlier than intermittent measurements. The aim of this study was to determine frequency and duration of vital sign deviations using continuous monitoring compared to manual measurements. A secondary analysis was to compare deviations in patients admitted to ICU or having fatal outcome vs. those that were not.Methods: Two wireless sensors continuously monitored (CM) respiratory rate (RR), heart rate (HR), and peripheral arterial oxygen saturation (SpO2). Frequency and duration of vital sign deviations were compared with point measurements performed by clinical staff according to regional guidelines, the National Early Warning Score (NEWS).Results: SpO2 < 92% for more than 60 min was detected in 92% of the patients with CM vs. 40% with NEWS (p < .00001). RR > 24 breaths per minute for more than 5 min were detected in 70% with CM vs. 33% using NEWS (p = .0001). HR ≥ 111 for more than 60 min was seen in 51% with CM and 22% with NEWS (p = .0002). Patients admitted to ICU or having fatal outcome had longer durations of RR > 24 brpm (p = .01), RR > 21 brpm (p = .01), SpO2 < 80% (p = .01), and SpO2 < 85% (p = .02) compared to patients that were not.Conclusion: Episodes of desaturation and tachypnea in hospitalized patients with COVID‐19 infection are common and often not detected by routine measurements.Keywords
Funding Information
- Innovationsfonden
- Novo Nordisk Fonden (NNF20SA0062833)
This publication has 16 references indexed in Scilit:
- Trajectories of vital signs in patients with COVID-19Resuscitation, 2020
- Comparison of Hospitalized Patients With ARDS Caused by COVID-19 and H1N1Chest, 2020
- Current Evidence for Continuous Vital Signs Monitoring by Wearable Wireless Devices in Hospitalized Adults: Systematic ReviewJournal of Medical Internet Research, 2020
- Early warning scores for detecting deterioration in adult hospital patients: systematic review and critical appraisal of methodologyBMJ, 2020
- Challenges With Continuous Pulse Oximetry Monitoring and Wireless Clinician Notification Systems After Surgery: Reactive Analysis of a Randomized Controlled TrialJMIR Medical Informatics, 2019
- The value of vital sign trends in predicting and monitoring clinical deterioration: A systematic reviewPLOS ONE, 2019
- Defining the Incidence of Cardiorespiratory Instability in Patients in Step-down Units Using an Electronic Integrated Monitoring SystemArchives of internal medicine (1960), 2008
- A comparison of Antecedents to Cardiac Arrests, Deaths and EMergency Intensive care Admissions in Australia and New Zealand, and the United Kingdom—the ACADEMIA studyResuscitation, 2004
- Association between clinically abnormal observations and subsequent in-hospital mortality: a prospective studyResuscitation, 2004
- World Medical Association Declaration of Helsinki: Ethical Principles for Medical Research Involving Human Subjects2003