The Effect of Bench Model Fidelity on Fluoroscopy-Guided Transforaminal Epidural Injection Training
Authors:
- Srinivas ChiravuriSCSrinivas Chiravuri
- R. Brent StansfieldRSR. Brent Stansfield
- Chad M. BrummettCBChad M. Brummett
- Stanley J. HamstraSHStanley J. Hamstra
- 1 January 2013
- journal article
- research article
- Published by BMJ in Regional Anesthesia & Pain Medicine
- Vol. 38 (2) , 155-160
Abstract
The purpose of this study was to determine whether high-fidelity simulators provide greater benefit than low-fidelity models in training fluoroscopy-guided transforaminal epidural injection. This educational study was a single-center, prospective, randomized 3-arm pretest-posttest design with a control arm. Eighteen anesthesia and physical medicine and rehabilitation residents were instructed how to perform a fluoroscopy-guided transforaminal epidural injection and assessed by experts on a reusable injectable phantom cadaver. The high- and low-fidelity groups received 30 minutes of supervised hands-on practice according to group assignment, and the control group received 30 minutes of didactic instruction from an expert. We found no differences at posttest between the high- and low-fidelity groups on global ratings of performance (P = 0.17) or checklist scores (P = 0.81). Participants who received either form of hands-on training significantly outperformed the control group on both the global rating of performance (control vs low-fidelity, P = 0.0048; control vs high-fidelity, P = 0.0047) and the checklist (control vs low-fidelity, P = 0.0047; control vs high-fidelity, P = 0.0047). Training an epidural procedure using a low-fidelity model may be equally effective as training on a high-fidelity model. These results are consistent with previous research on a variety of interventional procedures and further demonstrate the potential impact of simple, low-fidelity training models.Keywords
This publication has 14 references indexed in Scilit:
- A Low-Cost, Durable, Combined Ultrasound and Fluoroscopic Phantom for Cervical Transforaminal InjectionsRegional Anesthesia & Pain Medicine, 2012
- A Novel Actuator for Simulation of Epidural Anesthesia and Other Needle Insertion ProceduresSimulation in Healthcare: The Journal of the Society for Simulation in Healthcare, 2010
- Relative effectiveness of high‐ versus low‐fidelity simulation in learning heart soundsMedical Education, 2009
- Clinical Impact of Epidural Anesthesia Simulation on Short- and Long-term Learning CurveRegional Anesthesia & Pain Medicine, 2009
- Fiberoptic Oral IntubationAnesthesiology, 2008
- Inexpensive Phantom for Fluoroscopy Guided Nerve Block TrainingPain Medicine, 2008
- Teaching Technical Skills to Surgical ResidentsClinical Orthopaedics and Related Research, 2006
- See One, Do One, Teach One: Advanced Technology in Medical EducationAcademic Emergency Medicine, 2004
- The Educational Impact of Bench Model Fidelity on the Acquisition of Technical SkillAnnals of Surgery, 2004
- Testing technical skill via an innovative “bench station” examinationThe American Journal of Surgery, 1997