Current developments in cardiac rhythm management devices
- 27 June 2018
- journal article
- review article
- Published by Springer Nature in Clinical Research in Cardiology
- Vol. 107 (S2) , 100-104
Abstract
Endocardial pacing has experienced a tremendous evolution since the 1960s. A lot of challenges associated with pacemaker and ICD devices have already been successfully targeted. However, a relevant number of problems have not been solved to date. Not all patients with accepted indication for biventricular pacing have benefited from cardiac resynchronisation therapy (CRT) despite extensive efforts to reduce the rate of non-responders. Current strategies to optimize lead position, multipolar left-ventricular (LV) pacing leads, new strategies to gain access to the left-ventricle (atrial transseptal or ventricular transseptal access) or alternative right-ventricular (septal, His bundle pacing) pacing sites, and “leadless” LV pacing have the potential to increase response to device-based heart-failure treatment. The opportunity of pacemaker and ICD remote monitoring led to relevant improvements in therapy management by timely detection of events requiring medical or invasive interventions (e.g., external cardioversion of atrial fibrillation, increasing effective biventricular pacing, catheter ablation of ventricular tachycardias, or changes in heart-failure medication). Two completely endocardial leadless “all-in-one” pacemaker systems recently became available. Besides these innovations, new “synergistic” therapy concepts combining catheter ablation and device therapy proved to affect clinical endpoints (e.g., ATAAC study and CASTLE-AF study).Keywords
This publication has 17 references indexed in Scilit:
- Reduced Mortality Associated With Quadripolar Compared to Bipolar Left Ventricular Leads in Cardiac Resynchronization TherapyJACC: Clinical Electrophysiology, 2016
- Ablation Versus Amiodarone for Treatment of Persistent Atrial Fibrillation in Patients With Congestive Heart Failure and an Implanted DeviceCirculation, 2016
- A Leadless Intracardiac Transcatheter Pacing SystemThe New England journal of medicine, 2016
- Electrophysiologic Insights Into Site of Atrioventricular BlockJACC: Clinical Electrophysiology, 2015
- Percutaneous Implantation of an Entirely Intracardiac Leadless PacemakerThe New England journal of medicine, 2015
- The Relationship Between Level of Adherence to Automatic Wireless Remote Monitoring and Survival in Pacemaker and Defibrillator PatientsJACC, 2015
- Remote Monitoring of Implantable Cardioverter-DefibrillatorsJACC, 2015
- Computer Modelling for Better Diagnosis and Therapy of Patients by Cardiac Resynchronisation TherapyArrhythmia and Electrophysiology Review, 2015
- Biophysical Modeling to Simulate the Response to Multisite Left Ventricular Stimulation Using a Quadripolar Pacing LeadPacing and Clinical Electrophysiology, 2011
- Effects of biventricular pacing and scar size in a computational model of the failing heart with left bundle branch blockMedical Image Analysis, 2009