The relationship between ultrasonic backscatter and trabecular anisotropic microstructure in cancellous bone
Authors:
- 11 February 2014
- journal article
- conference paper
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 115 (6) , 064906
Abstract
To investigate the relationship between ultrasonic backscatter and trabecular microstructure, ultrasonic backscatter measurements were performed on cylindrical bovine cancellous bone samples in vitro. The backscatter signals from different specimen angles were obtained by rotating the specimen at various central frequencies. The backscatter signal varied a lot as the specimen angle changed. The main trabecular alignment (MTA) orientation was estimated by the maximum of signal energy and integrated reflection coefficient, or the minor axis of fitted ellipse for apparent integrated backscatter and the backscattered spectrum centroid frequency versus specimen angle. The degree of anisotropy (DA) was estimated by the eccentricity of the fitted ellipse with highly significant correlations. The MTA orientation and DA value estimation method proposed in this study is useful for ultrasonic cancellous bone assessment.Keywords
Funding Information
- NSFC (11174060)
This publication has 26 references indexed in Scilit:
- Feasibility of Bone Assessment with Ultrasonic Backscatter Signals in NeonatesUltrasound in Medicine & Biology, 2013
- Relationships of quantitative ultrasound parameters with cancellous bone microstructure in human calcaneus in vitroThe Journal of the Acoustical Society of America, 2012
- Osteoporosis: now and the futureThe Lancet, 2011
- Influence of cancellous bone microstructure on two ultrasonic wave propagations in bovine femur: An in vitro studyThe Journal of the Acoustical Society of America, 2010
- The relationship between fractures and DXA measures of BMD in the distal femur of children and adolescents with cerebral palsy or muscular dystrophyJournal of Bone and Mineral Research, 2010
- Measurement of tortuosity in aluminum foams using airborne ultrasoundUltrasonics, 2010
- Quantitative computed tomography (QCT) of the forearm using general purpose spiral whole-body CT scanners: Accuracy, precision and comparison with dual-energy X-ray absorptiometry (DXA)Bone, 2009
- Ultrasonic characterization of human trabecular bone microstructurePhysics in Medicine & Biology, 2006
- Predictive Value of BMD for Hip and Other FracturesJournal of Bone and Mineral Research, 2005
- Ultrasonic characterization of human cancellous bone using transmission and backscatter measurements: relationships to density and microstructureBone, 2002