Navigator-Gated Free-Breathing Three-Dimensional Balanced Fast Field Echo (TrueFISP) Coronary Magnetic Resonance Angiography
Authors:
- Elmar SpuentrupESElmar Spuentrup
- Peter BörnertPBPeter Börnert
- René M. BotnarRBRené M. Botnar
- Jan P. GroenJGJan P. Groen
- Warren J. ManningWMWarren J. Manning
- Matthias StuberMSMatthias Stuber
- 1 November 2002
- journal article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 37 (11) , 637-642
Abstract
Recent developments of MR imaging equipment enabled high-quality steady state-free-precession (Balanced FFE, True-FISP) MR-imaging with a substantial 'T2 like' contrast, resulting in a high signal intensity of the blood-pool without the application of exogenous contrast agents. It is hypothesized that Balanced-FFE may be valuable for contrast enhancement in 3D free-breathing coronary MRA. Navigator-gated free-breathing cardiac triggered coronary MRA was performed in 10 healthy adult subjects and three patients with radiograph defined coronary artery disease using a segmented k-space 3D Balanced FFE imaging sequence. High contrast-to-noise ratio between the blood-pool and the myocardium (29 +/- 8) and long segment visualization of both coronary arteries could be obtained in about 5 minutes during free breathing using the present navigator-gated Balanced-FFE coronary MRA approach. First patient results demonstrated successful display of coronary artery stenoses. Balanced FFE offers a potential alternative for endogenous contrast enhancement in navigator-gated free-breathing 3D coronary MRA. The obtained results together with the relatively short scanning time warrant further studies in larger patient collectives.Keywords
This publication has 16 references indexed in Scilit:
- Contrast agent-enhanced, free-breathing, three-dimensional coronary magnetic resonance angiographyJournal of Magnetic Resonance Imaging, 1999
- Double-oblique free-breathing high resolution three-dimensional coronary magnetic resonance angiographyJACC, 1999
- Submillimeter Three-dimensional Coronary MR Angiography with Real-time Navigator Correction: Comparison of Navigator LocationsRadiology, 1999
- Novel real-time R-wave detection algorithm based on the vectorcardiogram for accurate gated magnetic resonance acquisitionsMagnetic Resonance in Medicine, 1999
- Improved Coronary Artery Definition With T2-Weighted, Free-Breathing, Three-Dimensional Coronary MRACirculation, 1999
- Blood pool agent strongly improves 3D magnetic resonance coronary angiography using an inversion pre-pulseMagnetic Resonance in Medicine, 1999
- Three‐dimensional MRI of coronary arteries using an intravascular contrast agentMagnetic Resonance in Medicine, 1998
- Invited. Remember true FISP? a high SNR, near 1‐second imaging method for T2‐like contrast in interventional MRI at .2 TJournal of Magnetic Resonance Imaging, 1998
- Coronary Angiography with Magnetization‐Prepared T2 ContrastMagnetic Resonance in Medicine, 1995
- Coronary arteries: three-dimensional MR imaging with fat saturation and magnetization transfer contrast.Radiology, 1993