Micromachined Tactile Sensor Array for RTSA
Open Access
- 21 November 2021
- journal article
- research article
- Published by MDPI AG in Micromachines
- Vol. 12 (11) , 1430
Abstract
This work presents a polymer-based tactile capacitive sensor capable of measuring joint reaction forces of reverse total shoulder arthroplasty (RTSA). The capacitive sensor contains a polydimethylsiloxane (PDMS) dielectric layer with an array of electrodes. The sensor was designed in such a way that four components of glenohumeral contact forces can be quantified to help ensure proper soft tissue tensioning during the procedure. Fabricated using soft lithography, the sensor has a loading time of approximately 400 ms when a 14.13 kPa load is applied and has a sensitivity of 1.24 × 10−3 pF/kPa at a load of 1649 kPa. A replica RTSA prothesis was 3D printed, and the sensor was mounted inside the humeral cap. Four static right shoulder positions were tested, and the results provided an intuitive graphical description of the pressure distribution across four quadrants of the glenohumeral joint contact surface. It may help clinicians choose a right implant size and offset that best fit a patient’s anatomy and reduce postoperative biomechanical complications such as dislocation and stress fracture of the scapula.Keywords
This publication has 32 references indexed in Scilit:
- Prosthesis design and placement in reverse total shoulder arthroplastyJournal of Orthopaedic Surgery and Research, 2015
- A flexible PDMS capacitive tactile sensor with adjustable measurement range for plantar pressure measurementMicrosystem Technologies, 2013
- The use of the reverse shoulder arthroplasty for treatment of failed total shoulder arthroplastyJournal of Shoulder and Elbow Surgery, 2012
- A History of Reverse Total Shoulder ArthroplastyClinical Orthopaedics and Related Research, 2011
- Total hip joint prosthesis for in vivo measurement of forces and momentsMedical Engineering & Physics, 2009
- The Reverse Total Shoulder ProsthesisJournal of Bone and Joint Surgery, 2007
- Neer Award 2005: The Grammont reverse shoulder prosthesis: Results in cuff tear arthritis, fracture sequelae, and revision arthroplastyJournal of Shoulder and Elbow Surgery, 2006
- Grammont reverse prosthesis: Design, rationale, and biomechanicsJournal of Shoulder and Elbow Surgery, 2005
- Shoulder arthroplasty for the treatment of the sequelae of fractures of the proximal humerusJournal of Shoulder and Elbow Surgery, 2001
- Prosthetic Arthroplasty of the ShoulderActa Orthopaedica, 1983