A Dual-Armed Robotic Puncture System: Design, Implementation and Preliminary Tests
Open Access
- 28 February 2022
- journal article
- research article
- Published by MDPI AG in Electronics
- Vol. 11 (5) , 740
Abstract
Traditional renal puncture surgery requires manual operation, which has a poor puncture effect, low surgical success rate, and high incidence of postoperative complications. Robot-assisted puncture surgery can effectively improve the accuracy of punctures, improve the success rate of surgery, and reduce the occurrence of postoperative complications. This paper provides a dual-armed robotic puncture scheme to assist surgeons. The system is divided into an ultrasound scanning arm and a puncture arm. Both robotic arms with a compliant positioning function and master–slave control function are designed, respectively, and the control system is achieved. The puncture arm’s position and posture are decoupled by the wrist RCM mechanism and the arm decoupling mechanism. According to the independent joint control principle, the compliant positioning function is realized based on the single-joint human–computer interactive admittance control. The simulation and tests verify its functions and performance. The differential motion incremental master–slave mapping strategy is used to realize the master–slave control function. The error feedback link is introduced to solve the cumulative error problem in the master–slave control. The dual-armed robotic puncture system prototype is established and animal tests verify the effectiveness.Keywords
Funding Information
- National Key Research and Development Program of China (2017YFB1303101)
This publication has 22 references indexed in Scilit:
- Robotic systems for percutaneous needle-guided interventionsMinimally Invasive Therapy & Allied Technologies, 2014
- Raven-II: An Open Platform for Surgical Robotics ResearchIEEE Transactions on Biomedical Engineering, 2012
- CT‐guided robotic needle biopsy of lung nodules with respiratory motion – experimental system and preliminary testThe International Journal of Medical Robotics and Computer Assisted Surgery, 2012
- DLR MiroSurge: a versatile system for research in endoscopic telesurgeryInternational Journal of Computer Assisted Radiology and Surgery, 2009
- Robot-assisted biopsy using ultrasound guidance: initial results from in vitro testsEuropean Radiology, 2004
- Timing of Complications in Percutaneous Renal BiopsyJournal of the American Society of Nephrology, 2004
- The ZEUS robotic system: experimental and clinical applicationsSurgical Clinics of North America, 2003
- Acubot: a robot for radiological interventionsIEEE Transactions on Robotics and Automation, 2003
- Case Study on Haptic Devices: Human-Induced Instability in Powered Hand ControllersJournal of Guidance, Control, and Dynamics, 1995
- Stability and Performance Limits of Interaction ControllersJournal of Dynamic Systems, Measurement, and Control, 1992