Hospital‐wide survey of the adequacy in the number of vascular catheters and catheter lumens
- 9 December 2013
- journal article
- research article
- Published by Wiley in Journal of Hospital Medicine
- Vol. 9 (1) , 35-41
Abstract
BACKGROUND: Removal of unnecessary catheters has been proposed as an important measure to reduce catheter‐related morbidity. Nevertheless, there is scarce information about the potential magnitude of such intervention.OBJECTIVE: The present study was aimed at analyzing the appropriateness of use of vascular catheters and catheter lumens in the inpatient setting.DESIGN: Cross‐sectional survey.SETTING: The entire population of adult inpatients admitted to a 1368‐bed tertiary‐care hospital in a single day.MEASUREMENTS: We used a set of preestablished criteria to evaluate the appropriateness of use of vascular catheters and catheter lumens according to the number and administration regimen of intravenous drugs.RESULTS: Out of 834 patients, 575 (68.9%) had ≥1 vascular catheters in place on the day of the survey. The type and distribution of the 703 surveyed catheters were peripheral venous catheter, 80.6%; central venous catheter, 15.8%; and arterial catheter, 3.6%. We found an overall mean of 2.06 ± 0.82 lumens per catheter, with significant differences between intensive care units and conventional wards (P < 0.0001). Based on our criteria, 126 out of 575 patients (21.9%) had an inappropriate number of catheters (medical wards, 20.0%; surgical wards, 23.9%; intensive care units, 26.3%), and 631 out of 14248 nonarterial catheter lumens (43.6%) were considered unnecessary.CONCLUSIONS: Significant room exists for improving the adequacy of the number of vascular catheters and catheter lumens as a potentially useful tool for decreasing the incidence of catheter‐related bloodstream infection. Journal of Hospital Medicine 2014;9:35–41. © 2013 Society of Hospital MedicineKeywords
This publication has 26 references indexed in Scilit:
- Inappropriate intravascular device use: a prospective studyJournal of Hospital Infection, 2011
- Guidelines for the Prevention of Intravascular Catheter-related InfectionsClinical Infectious Diseases, 2011
- Hospital-wide survey of the use of central venous cathetersJournal of Hospital Infection, 2011
- Preventing Catheter‐Related Bloodstream Infections outside the Intensive Care Unit: Expanding Prevention to New SettingsClinical Infectious Diseases, 2010
- Strategies to Prevent Central Line–Associated Bloodstream Infections in Acute Care HospitalsInfection Control & Hospital Epidemiology, 2008
- Multilumen Central Venous Catheters Increase Risk for Catheter-Related Bloodstream Infection: Prospective Surveillance StudyInfection, 2008
- Unnecessary Use of Central Venous Catheters: The Need to Look Outside the Intensive Care UnitInfection Control & Hospital Epidemiology, 2004
- Rates of infection for single-lumen versus multilumen central venous catheters: A meta-analysisCritical Care Medicine, 2003
- Use of Triple‐Lumen Subclavian Catheters for Administration of Total Parenteral NutritionJournal of Parenteral and Enteral Nutrition, 1992
- Infection Rate for Single Lumen v Triple Lumen Subclavian CathetersInfection Control & Hospital Epidemiology, 1988