Supercontinence following Antireflux Surgery – Evaluation by pH-Metry

Authors:
  • HWH.F. Weiser
    H.F. Weiser
  • YWY.Q. Wu
    Y.Q. Wu
  • JSJ.R. Siewert
    J.R. Siewert

Abstract
Fundoplication as well as silicone antireflux prosthesis are procedures of known efficacy. Both procedures are accompanied in 10–15% of the cases by cuff and prosthesis complications. We investigated whether fundoplication and silicone prosthesis create an unphysiological antireflux barrier, which may explain the described postoperative symptoms. The results of pH-metry show that a significant reduction of 24 h reflux may be achieved by both antireflux operations. In this regard, particular importance may be attributed to the almost complete suppression of postprandial gastroesophageal reflux from 7.7 ± 2.6 to 1.3 ± 0.5 min/h following fundoplication and to 1.2 ± 0.1 min/h following implantation of the prosthesis (p < 0.001). We conclude that both operative procedures create an unphysiological antireflux barrier which may be the cause of postoperative disorders in the sense of supercontinence of the gastroesophageal sphincter.