In vivo anterior tibial post contact after posterior stabilizing total knee arthroplasty
Authors:
- 7 June 2007
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 25 (11) , 1447-1453
Abstract
Anterior polyethylene post failure in posterior stabilizing total knee arthroplasty (TKA) has been reported in recent patient follow‐up studies. However, no data have been reported on the biomechanic interaction between the anterior tibial post and femoral component in posterior stabilizing TKA patients under physiological conditions. The objective of this study was to measure the in vivo anterior tibial post contact area at full knee extension using a dual‐orthogonal fluoroscopic imaging technique. Eleven osteoarthritic patients were investigated after posterior stabilizing TKA to measure the contact between the femoral component box and anterior aspect of the tibial post. Anterior tibial post contact, ranging between 0.5 and 80.9 mm2, was detected in 63% of the healthy patients (seven out of the eleven patients) at weight‐bearing full extension of the knee. The patients with anterior tibial post contact had significantly higher hyperextension angles (−8.4 ± 4.3°) than those without contact (1.4 ± 7.2°). A statistically significant difference was also detected in the femoral component flexion with respect to the femoral shaft between the patients with anterior post contact (2.7 ± 2.7°) and without anterior post contact (−1.3 ± 2.2°). These data indicated that anterior post contact did occur in hyperextension within posterior stabilizing TKA patients. While excessive anterior tibial post contact may cause polyethylene wear and potentially lead to post failure, the tibial post may also act as a substitute for the ACL at low flexion, thus providing stability to the joint after posterior stabilizing TKA. © 2007 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 25:1447–1453, 2007Keywords
This publication has 19 references indexed in Scilit:
- Determination of in-vivo articular cartilage contact areas of human talocrural joint under weightbearing conditionsOsteoarthritis and Cartilage, 2006
- Investigation of in vivo 6DOF total knee arthoplasty kinematics using a dual orthogonal fluoroscopic systemJournal of Orthopaedic Research, 2006
- Influence of tibial component posterior slope on in vivo knee kinematics in fixed-bearing total knee arthroplastyJournal of Orthopaedic Research, 2006
- Three-Dimensional Tibiofemoral Articular Contact Kinematics of a Cruciate-Retaining Total Knee ArthroplastyJournal of Bone and Joint Surgery, 2006
- An Optimized Image Matching Method for Determining In-Vivo TKA Kinematics with a Dual-Orthogonal Fluoroscopic Imaging SystemJournal of Biomechanical Engineering, 2006
- Anterior tibial post impingement in a posterior stabilized total knee arthroplastyJournal of Orthopaedic Research, 2005
- Fracture of the polyethylene tibial post in a NexGen posterior-stabilized knee prosthesisThe Journal of Arthroplasty, 2004
- Polyethylene post failure in posterior stabilized total knee arthroplastyThe Journal of Arthroplasty, 2004
- Surface Damage on Open Box Posterior-Stabilized Polyethylene Tibial InsertsClinical Orthopaedics and Related Research, 2003
- Fracture of the polyethylene tibial post in posterior stabilized (Insall Burstein II) total knee arthroplastyThe Journal of Arthroplasty, 2000