In vivo biological performance of composites combining micro-macroporous biphasic calcium phosphate granules and fibrin sealant
Authors:
- 11 March 2005
- journal article
- research article
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 125 (3) , 153-159
Abstract
Introduction Fibrin glues are currently used by surgeons and can facilitate the handling of biomaterials. Combining fibrin glue with calcium phosphate bioceramics gives a mouldable composite that cements the granules into the implantation site. In addition to the mechanical aspect of the composite, it has been suggested that the mixture also promotes wound healing. These human blood derivatives contain natural (aprotinin) or synthetic (tranexamic acid) antifibrinolytic substances. We compared the bioactivity of two composites combining calcium phosphate granules with two different types of fibrin glue, one with aprotinin and the other with tranexamic acid. Materials and methods The composite was composed of fibrin glue (Tissucol) and 1 to 2 mm granules of biphasic calcium phosphate granules (MBCP) with a volume ratio of 1 for 2. Bone cavities were drilled in 12 New Zealand rabbits and filled with a composite with aprotinin-fibrin glue on the right condyle and one with tranexamic acid-fibrin glue on the left condyle. The rabbits were randomized into two groups: 3 and 6 weeks of delay. Light microscopy, scanning electron microscopy and image analysis were performed. Results No adverse reactions were observed in either sample. Bony ingrowth associated with bioceramic resorption by osteoclastic TRAP-positive cells was noted. No significant difference was observed between the two composites. The bony ingrowth and ceramic resorption were qualitatively and quantitatively similar with both composites. Conclusion This study demonstrated that the choice of a natural (aprotinin) or synthetic (tranexamic acid) antifibrinolytic agent in the fibrin sealant associated with calcium phosphate granules and used as a bone substitute had no effect on the bioactivity of the composite. It remained efficient in bone reconstruction, no adverse effects were observed, and the bony ingrowth was qualitatively and quantitatively equivalent with the two types of fibrin sealant.Keywords
This publication has 49 references indexed in Scilit:
- Antifibrinolytic Additives to Fibrin Glue for Laparoscopic Wound Closure in Urinary TractJournal of Endourology, 1999
- Choc anaphylactique à la colle biologiqueAnnales Françaises d'Anesthésie et de Réanimation, 1997
- Triosite Implants and Fibrin Glue in the Treatment of Atrophic Rhinitis: Technique and ResultsThe Laryngoscope, 1996
- Fibrin sealant: summary of a conference on characteristics and clinical usesTransfusion, 1995
- An Autologous Fibrin Tissue Adhesive With Greater Bonding PowerJAMA Otolaryngology–Head & Neck Surgery, 1995
- Osteoclastic resorption of Ca-P biomaterials implanted in rabbit boneCalcified Tissue International, 1993
- Macroporous Biphasic Calcium Phosphate Efficiency in Mastoid Cavity Obliteration: Experimental and Clinical FindingsAnnals of Otology, Rhinology & Laryngology, 1992
- Immunophenotypic differences between osteoclasts and macrophage polykaryons: immunohistological distinction and implications for osteoclast ontogeny and function.Journal of Clinical Pathology, 1990
- Fibrin glue as cement for HA-granulesJournal of Cranio-Maxillofacial Surgery, 1989
- Die Technik der FibrinspongiosaplastikArchives of orthopaedic and trauma surgery, 1977