Single-Sensor Control of LCL-Filtered Grid-Connected Inverters
Open Access
- 19 March 2019
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 7, 38481-38494
Abstract
Owing to the filter resonance and background harmonics, the current control for the LCL-filtered grid-connected inverter should be carefully designed to ensure stable operation. Prior-art current control methods normally require extra sensors to achieve the damping of the resonance, or sophisticated active damping should be employed. Both increase the overall system cost and complexity. In this context, an improved control strategy is proposed for LCL-filtered inverters. The proposed control method utilizes a novel reduced-order observer in a way that only one current sensor is required for stable operation (i.e., resonance and harmonics are effectively attenuated). More specifically, the reduced-order observer embeds the dynamics of the grid voltage, where the estimated grid information is used for synchronization in a phase-locked loop. The estimated state variables of the observer are then used for the controller design. Furthermore, to achieve active damping and suppress the influence of grid voltage distortions on the current quality, a multi-resonant state-space controller is proposed, where a linear quadratic regulator method is employed to obtain the optimal gain. Simulations and experimental tests are performed on a 3-kW grid-connected inverter system with an LCL filter. The results demonstrate the effectiveness of the proposed method in terms of robust active damping and strong harmonic attenuation, and thus the inverter achieves a good power quality with only one current sensor.Keywords
Funding Information
- National Natural Science Foundation of China (51677195)
- National Natural Science Foundation of China (61573384)
- Central South University (2019CX0003)
- Fundamental Research Funds in Central South University (2018zzts530)
This publication has 40 references indexed in Scilit:
- Observer-Based State-Space Current Control for a Three-Phase Grid-Connected Converter Equipped With an LCL FilterIEEE Transactions on Industry Applications, 2013
- Robust proportional resonant regulator for grid-connected voltage source inverter (VSI) using direct pole placement design methodIET Power Electronics, 2012
- Small-Signal Modeling of Digitally Controlled Grid-Connected Inverters With $LCL$ FiltersIEEE Transactions on Industrial Electronics, 2012
- Filter-Based Active Damping of Voltage Source Converters With $LCL$ FilterIEEE Transactions on Industrial Electronics, 2010
- Explicit Model-Predictive Control of a PWM Inverter With an LCL FilterIEEE Transactions on Industrial Electronics, 2008
- A Simple Voltage Sensorless Active Damping Scheme for Three-Phase PWM Converters With an $LCL$ FilterIEEE Transactions on Industrial Electronics, 2008
- A Modified Direct Power Control Strategy Allowing the Connection of Three-Phase Inverters to the Grid Through $LCL$ FiltersIEEE Transactions on Industry Applications, 2007
- Model-based generation of low distortion currents in grid-coupled PWM-inverters using an LCL output filterIEEE Transactions on Power Electronics, 2006
- Stationary frame current regulation of PWM inverters with zero steady-state errorIEEE Transactions on Power Electronics, 2003
- A novel control to actively damp resonance in input LC filter of a three-phase voltage source converterIEEE Transactions on Industry Applications, 1997