Changes in in vivo knee loading with a variable‐stiffness intervention shoe correlate with changes in the knee adduction moment
Open Access
- 22 October 2010
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 28 (12) , 1548-1553
Abstract
External knee adduction moment can be reduced using footwear interventions, but the exact changes in in vivo medial joint loading remain unknown. An instrumented knee replacement was used to assess changes in in vivo medial joint loading in a single patient walking with a variable‐stiffness intervention shoe. We hypothesized that during walking with a load modifying variable‐stiffness shoe intervention: (1) the first peak knee adduction moment will be reduced compared to a subject's personal shoes; (2) the first peak in vivo medial contact force will be reduced compared to personal shoes; and (3) the reduction in knee adduction moment will be correlated with the reduction in medial contact force. The instrumentation included a motion capture system, force plate, and the instrumented knee prosthesis. The intervention shoe reduced the first peak knee adduction moment (13.3%, p = 0.011) and medial compartment joint contact force (12.3%; p = 0.008) compared to the personal shoe. The change in first peak knee adduction moment was significantly correlated with the change in first peak medial contact force (R2 = 0.67, p = 0.007). Thus, for a single subject with a total knee prosthesis the variable‐stiffness shoe reduces loading on the affected compartment of the joint. The reductions in the external knee adduction moment are indicative of reductions in in vivo medial compressive force with this intervention. © 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 28:1548–1553, 2010Keywords
This publication has 34 references indexed in Scilit:
- Changes in knee adduction moment, pain, and functionality with a variable‐stiffness walking shoe after 6 monthsJournal of Orthopaedic Research, 2010
- Effective gait patterns for offloading the medial compartment of the kneeJournal of Orthopaedic Research, 2009
- The effect of a subject‐specific amount of lateral wedge on knee mechanics in patients with medial knee osteoarthritisJournal of Orthopaedic Research, 2007
- In vivo medial and lateral tibial loads during dynamic and high flexion activitiesJournal of Orthopaedic Research, 2007
- In healthy subjects without knee osteoarthritis, the peak knee adduction moment influences the acute effect of shoe interventions designed to reduce medial compartment knee loadJournal of Orthopaedic Research, 2007
- An implantable telemetry device to measure intra-articular tibial forcesJournal of Biomechanics, 2005
- Dynamic load at baseline can predict radiographic disease progression in medial compartment knee osteoarthritisAnnals of the Rheumatic Diseases, 2002
- Interaction between active and passive knee stabilizers during level walkingJournal of Orthopaedic Research, 1991
- Upper Tibial OsteotomyClinical Orthopaedics and Related Research, 1984
- Properties of body segments based on size and weightJournal of Anatomy, 1967