Procedural Safety and Efficacy for Pulmonary Vein Isolation with the Novel Polarx™ Cryoablation System: A Propensity Score Matched Comparison with the Arctic Front™ Cryoballoon in the Setting of Paroxysmal Atrial Fibrillation
Author:
- Dhanunjaya LakkireddyDLDhanunjaya Lakkireddy
Open Access
- 31 October 2020
- journal article
- cardiology
- Published by Cardiofront, LLC in Journal of Atrial Fibrillation
- Vol. 14 (1) , 20200455
Abstract
Background The novel Polarx™ cryoablation system is currently being studied for atrial fibrillation (AF) ablation. To the best of our knowledge, no study comparing the novel cryoablation system with the standard Arctic Front™ cryoballoon is available in today’s literature. This study aims to compare Polarx™ and Arctic Front™ cryoballoon in terms of safety and efficacy. Methods From a total cohort of 202 patients who underwent pulmonary vein (PV) isolation for paroxysmal AF through cryoablation, a population of 30 patients who used Polarx™ were compared with 30 propensity-score matched patients who used Arctic Front™. Results Pulmonary vein occlusion and electrical isolation were achieved in all (100%) veins with a mean number of 1.09 ± 0.3 occlusion per vein using Polarx™ and 1.19 ± 0.5 occlusion per vein using Arctic Front™ (p = 0.6). Shorter procedure and fluoroscopy time were observed with Polarx™ group (60.5 ± 14.23 vs 73.43 ± 13.26 mins, p = 0.001; 12.83 ± 6.03 vs 17.23 ± 7.17 mins, p = 0.01, respectively). Lower cumulative freeze duration per vein was also observed with Polarx™ (203.38 ± 72.03 vs 224.9 ± 79.35 mins, p = 0.02). There was no significant difference in isolation time between the two groups (34.47 ± 21.23 vs 34.18 ± 26.79 secs, p = 0.9). Conclusions The novel Polarx™ cryoablation system showed similar efficacy in vein occlusion and isolation and safety profile when compared to Arctic Front™ cryoablation system. Procedure time, fluoroscopy time, and cumulative freeze duration were significantly lower with Polarx™ cryoablation system.Keywords
This publication has 30 references indexed in Scilit:
- The Incidence of Phrenic Nerve Injury During Pulmonary Vein Isolation Using the Second‐Generation 28 mm CryoballoonJournal of Cardiovascular Electrophysiology, 2014
- Second-generation cryoballoon ablation for paroxysmal atrial fibrillation: 1-year follow-upEP Europace, 2014
- Improved lesion formation using the novel 28 mm cryoballoon in atrial fibrillation ablation: analysis of biomarker releaseEP Europace, 2014
- Balloon warming time is the strongest predictor of late pulmonary vein electrical reconnection following cryoballoon ablation for atrial fibrillationHeart Rhythm, 2013
- Improved Procedural Efficacy of Pulmonary Vein Isolation Using the Novel Second‐Generation CryoballoonJournal of Cardiovascular Electrophysiology, 2012
- Single Transseptal Big Cryoballoon Pulmonary Vein Isolation using an Inner Lumen Mapping CatheterPacing and Clinical Electrophysiology, 2012
- Pulmonary vein isolation during cryoballoon ablation using the novel Achieve inner lumen mapping catheter: a feasibility studyEP Europace, 2012
- Efficacy and safety of cryoballoon ablation for atrial fibrillation: A systematic review of published studiesHeart Rhythm, 2011
- Efficacy and safety of pulmonary veins isolation by cryoablation for the treatment of paroxysmal and persistent atrial fibrillationEP Europace, 2011
- Efficacy of pulmonary vein isolation by cryoballoon ablation in patients with paroxysmal atrial fibrillationHeart Rhythm, 2008