Investigating the ocular temperature rise during femtosecond laser lens fragmentation: an in vitro study
- 21 October 2015
- journal article
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 253 (12) , 2203-2210
Abstract
To investigate the trend of temperature variation during lens fragmentation simulated by a femtosecond laser on an in vitro eye model. In our experimental study, a convex cylinder of gelatinous material, usually employed in femtosecond laser calibration, was used to simulate both an anterior segment and a crystalline lens during fragmentation performed with the Victus femtosecond laser (Technolas Perfect Vision GmbH, Germany; Bausch + Lomb Incorporated, USA). Two radiated energies (7000 nJ and 9000 nJ) and three cutting patterns (crosses, circles and cross + circle) were applied. Trends of temperature variation as a function of time were obtained using a T-type thermocouple. The maximum value of temperature rise during lens fragmentation ranged from 3.53 to 5.13 °C; the rise was directly proportional to the intensity of the radiated energy (7000 nJ or 9000 nJ) and the cutting pattern performed. This behavior was experimentally represented by an asymmetric function with a characteristic bell curve shape, whereas it was mathematically described by a transport diffusive model. Since the temperature rise at the fragmentation volume base resulted to be around 5 °C in our in vitro study, lens fragmentation performed using the Victus femtosecond laser might be considered safe form a thermal point of view.Keywords
This publication has 25 references indexed in Scilit:
- Comparison of Long-term Visual Outcome and IOL Position With a Single-optic Accommodating IOL After 5.5- or 6.0-mm Femtosecond Laser CapsulotomyJournal of Refractive Surgery, 2012
- Early Experience with the Femtosecond Laser for Cataract SurgeryOphthalmology, 2012
- Intraocular Lens Tilt and Decentration Measured By Scheimpflug Camera Following Manual or Femtosecond Laser–created Continuous Circular CapsulotomyJournal of Refractive Surgery, 2012
- Femtosecond phacoemulsificationCurrent Opinion in Ophthalmology, 2012
- Temperature increase in porcine cadaver iris during direct illumination by femtosecond laser pulsesJournal of Cataract & Refractive Surgery, 2011
- Simulation of the temperature increase in human cadaver retina during direct illumination by 150-kHz femtosecond laser pulsesJournal of Biomedical Optics, 2011
- Thermal study of longitudinal and torsional ultrasound phacoemulsificationJournal of Cataract & Refractive Surgery, 2010
- Initial Clinical Evaluation of an Intraocular Femtosecond Laser in Cataract SurgeryJournal of Refractive Surgery, 2009
- Thermography used for analysis and comparison of different cataract surgery procedures based on phacoemulsificationPhysiological Measurement, 2006
- Ultrasound thermal damage to rabbit corneas after simulated phacoemulsificationJournal of Cataract & Refractive Surgery, 2005