Handheld versus conventional ultrasound for assessing carotid artery in routine volunteers
Authors:
- 19 December 2022
- journal article
- research article
- Published by SAGE Publications in Clinical Hemorheology and Microcirculation
- Vol. 82 (3) , 255-263
Abstract
AIM: Carotid ultrasound is a key tool for the diagnosis and evaluation of cardio disease, and the measurement of carotid intima-media thickness (CIMT) and hemodynamic parameters is of paramount importance for the imaging method. The aim of this study was to evaluate the feasibility and accuracy of handheld ultrasound devices for measuring carotid parameters. METHODS: We performed a carotid ultrasound on 25 participants using a handheld ultrasound device and a conventional ultrasound machine. For each participant, max and mean CIMT of common carotid artery (CCA) and peak systolic velocity (PSV), end diastolic velocity (EDV) and resistive index (RI) of CCA, bilateral external carotid artery (ECA), internal carotid artery (ICA) and the vertebral artery were measured. Agreement and repeatability were evaluated by linear regression and Bland-Altman analysis. RESULTS: We found a good repeatability and consistent of handheld ultrasound device in measuring mean CIMT (r = 0.68, P < 0.01). Furthermore, there was a moderate to good agreement between handheld and conventional ultrasound systems in measuring max IMT, mean IMT, PSV, EDV and RI of CCA (0.73, 0.79, 0.52, 0.58 and 0.84, respectively). CONCLUSION: Handheld ultrasound devices were able to provide carotid IMT and hemodynamic parameters measurements similar to those of conventional ultrasound. Such capabilities of handheld ultrasound devices might be useful for the primary assessment of carotid in clinical work.Keywords
All Related Versions
This publication has 25 references indexed in Scilit:
- Diagnosis of Pericardial Effusion with a New Generation Hand-Carried Ultrasound Device in Cardiothoracic Intensive Care Unit PatientsActa Radiologica, 2012
- Diagnostic Performance of Handheld Echocardiography for the Assessment of Basic Cardiac Morphology and Function: A Validation Study in Routine Cardiac PatientsEchocardiography, 2012
- Stroke and Stroke Care in ChinaStroke, 2011
- Carotid and Vertebral Artery Doppler Ultrasound WaveformsUltrasound Quarterly, 2011
- Improved cardiovascular diagnostic accuracy by pocket size imaging device in non-cardiologic outpatients: the NaUSiCa (Naples Ultrasound Stethoscope in Cardiology) studyCardiovascular Ultrasound, 2010
- Ultraschallkriterien zur Graduierung von Stenosen der A. carotis interna – Revision der DEGUM-Kriterien und Transfer in NASCET-StenosierungsgradeUltraschall in der Medizin - European Journal of Ultrasound, 2010
- Arterial Stiffness, Vascular Disease, and Risk of Cardiovascular EventsCirculation, 2006
- Human factors as a source of error in peak Doppler velocity measurementJournal of Vascular Surgery, 2005
- Intimal plus medial thickness of the arterial wall: a direct measurement with ultrasound imaging.Circulation, 1986
- Measurement of blood flow by ultrasound: Accuracy and sources of errorUltrasound in Medicine & Biology, 1985