First Clinical Experience With the Alcon LADAR 6000 Excimer Laser
Authors:
- Francesco CaronesFCFrancesco Carones
- Luca VigoLVLuca Vigo
- Elena ScandolaESElena Scandola
- 1 November 2005
- journal article
- research article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 21 (6) , S781-S785
Abstract
PURPOSE: To evaluate the reliability and ergonomics and to assess the first clinical results provided by the new LADAR 6000 excimer laser used to correct myopia and astigmatism, both by conventional and wavefrontguided ablation. METHODS: Seventy-four consecutive eyes from 37 patients underwent LASIK as the first field evaluation protocol of the Alcon LADAR 6000 excimer laser. Forty-six eyes were treated by wavefront-guided ablation to correct a manifestspheroequivalent refractive error (MSRE) of -0.50 to -9.75 diopters (D) (mean: -4.19 D, cylinder range: 0.0 to -3.50 D). Twenty-eight eyes were treated by conventional ablation to correct MSRE of -1.00 to -7.00 D (mean: -3.11 D, cylinder range: 0.0 to -1.75 D). Uncorrected (UCVA) and best spectacle-corrected visual acuity (BSCVA), MSRE, and wavefront measurements were assessed. Follow-up was 3 months for all eyes. RESULTS: Three months after surgery, all eyes were within ?1.00 D of intended correction. Forty-three (93.5%) eyes treated with wavefront-guided ablation and 25 (89.3%) eyes treated with conventional ablation were within ?0.50 D. All eyes reached 2*20/25 UCVA. UCVA ^20/20 was reached in 45 (97.8%) wavefront-guided eyes and 26 (92.9%) conventional eyes; 37 (80.4%) wavefront-guided eyes and 17 (60.7%) conventional eyes had 20/16 UCVA. None of the eyes treated lost ^2 lines of BSCVA. CONCLUSIONS: The LADAR 6000 excimer laser results proved to be at least as accurate, predictable, and safe as the results currently achieved with the LADARVision4000 excimer laser. The improved microscope illumination enhances visibility for better consistency and ease of use. The better ergonomics and software design of this platform improved patient flow. [J Refract Surg. 2005;21: S781-S785.]Keywords
This publication has 12 references indexed in Scilit:
- Technological Improvements With the Alcon LADAR 6000 Excimer Laser PlatformJournal of Refractive Surgery, 2005
- Wavefront-guided Treatment of Abnormal Eyes Using the LADARVision PlatformJournal of Refractive Surgery, 2003
- Update on customized excimer ablations: recent developments reported in 2002Current Opinion in Ophthalmology, 2003
- LASIK correction of spherical hyperopia, hyperopic astigmatism, and mixed astigmatism with the LADARVision excimer laser systemOphthalmology, 2002
- Early clinical experience using custom excimer laser ablations to treat irregular astigmatismJournal of Cataract & Refractive Surgery, 2000
- Wavefront-guided Laser in situ Keratomileusis: Early Results in Three EyesJournal of Refractive Surgery, 2000
- Photorefractive Keratectomy For Hyperopia and Aphakia with a Scanning Spot Excimer LaserJournal of Refractive Surgery, 1997
- Automatic Eye Tracker for Excimer Laser Photorefractive KeratectomyJournal of Refractive Surgery, 1995
- A Prototype Erodible Mask Delivery System for the Excimer LaserOphthalmology, 1993
- Excimer Laser Instrumentation and Technique for Human Corneal SurgeryArchives of Ophthalmology (1950), 1989