Cardiac Troponin Assay Classification by Both Clinical and Analytical Performance Characteristics: A Study on Outcome Prediction
Authors:
Open Access
- 1 June 2013
- journal article
- research article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 59 (6) , 976-981
Abstract
BACKGROUND: Cardiac troponin assays have been classified according to whether they measure the 99th percentile concentration of a healthy reference population with imprecision (expressed as CV) of ≤10%, between 10% and 20%, or >20%. Assays in these categories have been deemed “guideline acceptable,” “clinically usable,” or “not acceptable,” respectively. We compared four widely used “clinically usable” cardiac troponin I (cTnI) assays with an assay designated “not acceptable” for accuracy in predicting the clinical outcome of death. METHODS: Blood was collected from 259 men and 249 women, mean (SD) age 68.8 (17.8) and 70.2 (17.8) years, respectively, admitted to the emergency department for suspected myocardial infarction. We measured cTnI by the Access, Architect, i-Stat, Stratus CS, and VIDAS assays. Deaths in this population were recorded over a 31-month period. RESULTS: We found VIDAS cTnI assay measurement CVs of 10% and 20% at concentrations of 0.04 and 0.02 μg/L, respectively. Comparing at the 10% CV cutoff concentration, VIDAS cTnI was less sensitive than the Access and Architect assays (P < 0.001) but more sensitive than i-Stat (P < 0.001) and Stratus CS (P < 0.001) in identifying patients with poor outcomes. At the 20% CV cutoff, the VIDAS assay was equivalent to the other assays in identifying patients with poor outcomes. CONCLUSIONS: For outcome prediction, the VIDAS cTnI assay was clinically equivalent or superior to other cTnI assays judged to be acceptable from a pure analytical standpoint. Thus, comparison of cardiac troponin assays should consider not only analytical performance, but also clinical performance characteristics.Keywords
Funding Information
- bioMérieux Clinical Diagnostics
This publication has 15 references indexed in Scilit:
- A New Season for Cardiac Troponin Assays: It’s Time to Keep a ScorecardClinical Chemistry, 2009
- Clinical Performance of Two Highly Sensitive Cardiac Troponin I AssaysClinical Chemistry, 2009
- Value of Cardiac Troponin I Cutoff Concentrations below the 99th Percentile for Clinical Decision-MakingClinical Chemistry, 2009
- Use of the bioMérieux VIDAS® troponin I ultra assay for the diagnosis of myocardial infarction and detection of adverse events in patients presenting with symptoms suggestive of acute coronary syndromeClinica Chimica Acta, 2008
- Persistent Cardiac Troponin I Elevation in Stabilized Patients After an Episode of Acute Coronary Syndrome Predicts Long-Term MortalityCirculation, 2007
- The Antibody Configurations of Cardiac Troponin I Assays May Determine Their Clinical PerformanceClinical Chemistry, 2006
- Troponin I as a Predictor of Coronary Heart Disease and Mortality in 70-Year-Old MenCirculation, 2006
- Analytical performance of the i-STAT cardiac troponin I assayClinica Chimica Acta, 2004
- Evaluation of Imprecision for Cardiac Troponin Assays at Low-Range ConcentrationsClinical Chemistry, 2004
- Clinical and Analytical Performance of the Liaison Cardiac Troponin I Assay in Unstable Coronary Artery Disease, and the Impact of Age on the Definition of Reference Limits. A FRISC-II SubstudyClinical Chemistry, 2003