Structural and Functional Associations of Macular Microcirculation in the Ganglion Cell-Inner Plexiform Layer in Glaucoma Using Optical Coherence Tomography Angiography
- 1 March 2018
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Glaucoma
- Vol. 27 (3) , 281-290
Abstract
Purpose: To quantify retinal microvasculature within the macular ganglion cell-inner plexiform layer (GCIPL) in primary open-angle glaucoma (POAG) and normal eyes, determine association of vessel parameters with structural and functional measures, and report diagnostic accuracy of vessel parameters. Methods: POAG and normal patients underwent 6×6 mm macula scans [Angioplex optical coherence tomography angiography (OCTA); Cirrus HD-OCT 5000]; and Humphrey Field Analyzer II-i 24-2 visual field (VF). Prototype software performed semiautomatic segmentation to create GCIPL en face images, and quantified vessel area density (VAD), vessel skeleton density (VSD), and vessel complexity index (VCI) for the macula (globally, hemifields, and 6 focal sectors). Linear regression assessed association of OCTA parameters with VF mean deviation (MD) and GCIPL thickness globally and focally. Results: A total of 34 POAG and 21 normal eyes were studied. VAD, VSD, and VCI were reduced in POAG versus normal (0.463 vs. 0.486, P=0.00029; 0.230 vs. 0.219, P=0.0014; 1.15 vs. 1.09, P=0.0044, respectively), with a trend of worsening with increased POAG severity. Reduced global VF MD was associated with reduced VAD and VCI, controlling for age and intereye correlation (P=0.0060, 0.0080; R 2=0.205, 0.211). Both superior and inferior hemifield MD were associated with corresponding VAD, VSD, and VCI (all PR 2 ranged from 0.12 to 0.29). Global GCIPL thickness was not associated with global OCTA parameters, and only inferior sector GCIPL thickness was associated with corresponding VAD, VSD, and VCI (PR 2 ranged from 0.15 to 0.16). Area under curves for VAD, VSD, and VCI were fair to good (0.83, 0.79, 0.82; respectively; P<0.0001). Conclusions: Glaucomatous eyes had reduced GCIPL microcirculation. OCTA parameters had stronger associations with functional rather than structural measures of glaucoma. This observation deserves further study.Keywords
This publication has 40 references indexed in Scilit:
- Projection-Resolved Optical Coherence Tomography Angiography of Macular Retinal Circulation in GlaucomaOphthalmology, 2017
- Detailed Vascular Anatomy of the Human Retina by Projection-Resolved Optical Coherence Tomography AngiographyScientific Reports, 2017
- Regional Comparisons of Optical Coherence Tomography Angiography Vessel Density in Primary Open-Angle GlaucomaAmerican Journal of Ophthalmology, 2016
- Quantitative Optical Coherence Tomography Angiography of Radial Peripapillary Capillaries in Glaucoma, Glaucoma Suspect, and Normal EyesAmerican Journal of Ophthalmology, 2016
- Repeatability and reproducibility of optic nerve head perfusion measurements using optical coherence tomography angiographyJournal of Biomedical Optics, 2016
- Optic Disc Perfusion in Primary Open Angle and Normal Tension Glaucoma Eyes Using Optical Coherence Tomography-Based MicroangiographyPLOS ONE, 2016
- Optic nerve head perfusion in normal eyes and eyes with glaucoma using optical coherence tomography-based microangiographyQuantitative Imaging in Medicine and Surgery, 2016
- Short-Term Enhancement of Visual Field Sensitivity in Glaucomatous Eyes Following Surgical Intraocular Pressure ReductionAmerican Journal of Ophthalmology, 2015
- Long term effect of trabeculectomy on retrobulbar haemodynamics in glaucomaOphthalmic and Physiological Optics, 2014
- Ultrahigh sensitive optical microangiography for in vivo imaging of microcirculations within human skin tissue bedsOptics Express, 2010