Lung- and Diaphragm-Protective Ventilation by Titrating Inspiratory Support to Diaphragm Effort: A Randomized Clinical Trial
Open Access
- 4 February 2022
- journal article
- research article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 50 (2) , 192-203
Abstract
OBJECTIVES: Lung- and diaphragm-protective ventilation is a novel concept that aims to limit the detrimental effects of mechanical ventilation on the diaphragm while remaining within limits of lung-protective ventilation. The premise is that low breathing effort under mechanical ventilation causes diaphragm atrophy, whereas excessive breathing effort induces diaphragm and lung injury. In a proof-of-concept study, we aimed to assess whether titration of inspiratory support based on diaphragm effort increases the time that patients have effort in a predefined “diaphragm-protective” range, without compromising lung-protective ventilation. DESIGN: Randomized clinical trial. SETTING: Mixed medical-surgical ICU in a tertiary academic hospital in the Netherlands. PATIENTS: Patients (n = 40) with respiratory failure ventilated in a partially-supported mode. INTERVENTIONS: In the intervention group, inspiratory support was titrated hourly to obtain transdiaphragmatic pressure swings in the predefined “diaphragm-protective” range (3–12 cm H2O). The control group received standard-of-care. MEASUREMENTS AND MAIN RESULTS: Transdiaphragmatic pressure, transpulmonary pressure, and tidal volume were monitored continuously for 24 hours in both groups. In the intervention group, more breaths were within “diaphragm-protective” range compared with the control group (median 81%; interquartile range [64–86%] vs 35% [16–60%], respectively; p < 0.001). Dynamic transpulmonary pressures (20.5 ± 7.1 vs 18.5 ± 7.0 cm H2O; p = 0.321) and tidal volumes (7.56 ± 1.47 vs 7.54 ± 1.22 mL/kg; p = 0.961) were not different in the intervention and control group, respectively. CONCLUSIONS: Titration of inspiratory support based on patient breathing effort greatly increased the time that patients had diaphragm effort in the predefined “diaphragm-protective” range without compromising tidal volumes and transpulmonary pressures. This study provides a strong rationale for further studies powered on patient-centered outcomes.Keywords
This publication has 45 references indexed in Scilit:
- Diaphragm weakness in mechanically ventilated critically ill patientsCritical Care, 2013
- Diaphragm dysfunction assessed by ultrasonography: Influence on weaning from mechanical ventilation*Critical Care Medicine, 2011
- Inspiratory muscle strength training improves weaning outcome in failure to wean patients: a randomized trialCritical Care, 2011
- Rapidly Progressive Diaphragmatic Weakness and Injury during Mechanical Ventilation in HumansAmerican Journal of Respiratory and Critical Care Medicine, 2011
- Increased duration of mechanical ventilation is associated with decreased diaphragmatic force: a prospective observational studyCritical Care, 2010
- Rapid Disuse Atrophy of Diaphragm Fibers in Mechanically Ventilated HumansThe New England journal of medicine, 2008
- Intermittent spontaneous breathing protects the rat diaphragm from mechanical ventilation effects*Critical Care Medicine, 2005
- Is Weaning Failure Caused by Low-Frequency Fatigue of the Diaphragm?American Journal of Respiratory and Critical Care Medicine, 2003
- Mechanical Ventilation Protects against Diaphragm Injury in Sepsis: Interaction of Oxidative and Mechanical StressesAmerican Journal of Respiratory and Critical Care Medicine, 2002
- Acute Left Ventricular Dysfunction during Unsuccessful Weaning from Mechanical VentilationAnesthesiology, 1988