Delayed Diagnosis and Treatment of an Occult Hemothorax Following Complicated Central Line Insertion Leads to Cardiac Arrest
Authors:
- 1 January 2022
- journal article
- Published by Association for Vascular Access in Journal of the Association for Vascular Access
- Vol. 27 (1) , 44-47
Abstract
A 2-year-old girl with acute myelogenous leukemia and thrombocytopenia (platelet count 26,000 per microliter) with marked generalized petechiae and bruising was scheduled for implantation of a central venous catheter with a subcutaneous port. After reviewing the patient’s electronic health records but without seeing the patient, who was in another hospital, the anesthetist asked the surgeon to order a platelet transfusion to increase the child’s platelet count to above 50,000 per microliter. The patient was transported to the operating room while still receiving the platelet transfusion, so a follow-up platelet count had not yet been obtained.After induction of general anesthesia, the assistant surgeon tried 10 times to cannulate either subclavian vein without using ultrasound guidance. He finally succeeded in cannulating the left subclavian vein and, after fluoroscopically confirming that the tip of the catheter was in the lower half of the superior vena cava, he closed the wound. The patient was then awakened from general anesthesia and transferred to the post-anesthesia care unit. The surgeons had not noticed a moderate left-sided hemothorax on the post-procedure chest radiograph. This finding was reported by the on-duty radiologist but not conveyed to the surgeons. The anesthesiologist, who remained in the operating room, was called to see the patient who was pale, crying inconsolably, with fluctuating blood pressure. Realizing the seriousness of the child’s bleeding condition, he alerted the patient’s surgeons and the pediatric intensive care physician, but they were unable to arrive at the child’s bedside for 30 minutes and 45 minutes, respectively, so the anesthesiologist ordered blood for an urgent transfusion. Before the child could be transfused, she suddenly collapsed and developed cardiac arrest accompanied by pulseless electrical activity (PEA). A “code blue” was called and the child was successfully resuscitated after about 20 minutes, following insertion of a thoracostomy drainage (chest) tube.Unfortunately, the surgeon had damaged an intercostal artery when he inserted the chest tube emergently, which caused further bleeding and two additional episodes of PEA arrest. The patient required bedside thoracotomy and a prolonged pediatric intensive care unit (PICU) stay, during which she developed a subdural hematoma and ischemic encephalopathy.This case highlights a cascade of preventable iatrogenic events after a common procedure that is generally considered low-risk. The delay in diagnosis and subsequent treatment of a hemothorax resulted in a preventable and devastating series of events. Both errors in judgment and errors in technique occurred, and the attending surgeon was ultimately responsible for the outcome. One of the primary roles of the surgical team is to mitigate risk once the risks and benefits of the planned procedure have been assessed and the surgeon agrees to perform the procedure. For central line insertions, the risks include initial catheter malposition and bleeding. The proceduralist must also be on the lookout for injury to surrounding structures (such as arteries, other veins, nerves, thoracic duct, lung, trachea, etc.) and perforations of the vein being accessed or large central veins or heart. If the catheter is malpositioned, it can contribute to delayed complications such as erosion of the catheter through the vein wall or heart, vessel thrombosis, vessel stenosis, and infection (such as central line-associated blood stream infection [CLABSI] or endocarditis). Occlusion of the central line and embolization of thrombus or air from careless flushing of the catheter are also known risks, especially in children with congenital heart disease and complete mixing lesions.1,2In this case, the patient was thrombocytopenic with clinical evidence of coagulopathy. Appropriately, a platelet transfusion was ordered and was running while the patient was on the way to the operating room. A follow-up platelet count would have provided some assurance that the procedure could be performed safely, with a manageable risk of serious bleeding.The next issue the surgeon had to address was choosing a surgical approach that would be most appropriate for this patient. In patients at serious risk for bleeding after central line placement, peripheral cannulation is a reasonable alternative to subclavian vein cannulation. Indeed, Kanji et al. showed that in patients undergoing extracorporeal membrane oxygenation, peripheral cannulation was associated with a marked reduction in blood product utilization (i.e., packed red blood cells, platelets, fresh frozen plasma, and cryoprecipitate transfusions) as well as decreased incidence of bleeding from the cannulation site (18% vs 64%).3 Although the patient population in that study had a different indication for central venous access than the patient in the current case, one can reasonably infer that peripheral cannulation would also be safer in patients with similar preexisting coagulopathy (such as a thrombocytopenic patient with a hematologic malignancy). In patients such as the two-year-old in this case, the risk of bleeding into the pleural space must be minimized as such bleeding is difficult to detect until there is a hemodynamic embarrassment, compared with bleeding outside the pleural space, such as in a subcutaneous tunnel. A facial vein cutdown or external jugular vein cutdown would have been safer approaches in this case, as these procedures mitigate the risk of bleeding and pneumothorax compared with the typical subclavian vein or internal jugular vein approach.1 Implanting chemotherapy ports via the external jugular vein is a reliable and safe approach in patients requiring long-term chemotherapy.4 Furthermore, in a retrospective analysis of pediatric patients, Bawazier et al. showed that Hickman central venous catheters inserted via open cutdown of the external jugular...Keywords
This publication has 13 references indexed in Scilit:
- Vascular Access in the Pediatric PopulationSurgical Clinics of North America, 2017
- Iatrogenic injury to the intercostal artery: aetiology, diagnosis and therapeutic interventionThorax, 2015
- Central line complicationsInternational Journal of Critical Illness and Injury Science, 2015
- Course and Variation of the Intercostal Artery by CT ScanChest, 2013
- Peripheral versus Central Cannulation for Extracorporeal Membrane Oxygenation: A Comparison of Limb Ischemia and Transfusion RequirementsThe Thoracic and Cardiovascular Surgeon, 2010
- Pleural procedures and thoracic ultrasound: British Thoracic Society pleural disease guideline 2010Thorax, 2010
- A study of the complications of small bore ‘Seldinger’ intercostal chest drainsRespirology, 2008
- Prospective Analysis of Percutaneous Central Venous Catheterization in Infants <4.0 kg Undergoing Cardiac SurgeryPediatric Cardiology, 2004
- Complications and Failures of Subclavian-Vein CatheterizationNew England Journal of Medicine, 1994