Design and control of a prosthetic leg for above-knee amputees operated in semi-active and active modes
Authors:
- 11 July 2016
- journal article
- Published by IOP Publishing in Smart Materials and Structures
- Vol. 25 (8) , 085009
Abstract
This paper proposes a new prosthesis operated in two different modes; the semi-active and active modes. The semi-active mode is achieved from a flow mode magneto-rheological (MR) damper, while the active mode is obtained from an electronically commutated (EC) motor. The knee joint part of the above knee prosthesis is equipped with the MR damper and EC motor. The MR damper generates reaction force by controlling the field-dependent yield stress of the MR fluid, while the EC motor actively controls the knee joint angle during gait cycle. In this work, the MR damper is designed as a two-end type flow mode mechanism without air chamber for compact size. On other hand, in order to predict desired knee joint angle to be controlled by EC motor, a polynomial prediction function using a statistical method is used. A nonlinear proportional-derivative controller integrated with the computed torque method is then designed and applied to both MR damper and EC motor to control the knee joint angle. It is demonstrated that the desired knee joint angle is well achieved in different walking velocities on the ground ground.Keywords
This publication has 16 references indexed in Scilit:
- CHAPTER 16. A Novel Medical Haptic Device Using Magneto-rheological Fluid2013
- Quantifying Dynamic Characteristics of Human Walking for Comprehensive Gait CycleJournal of Biomechanical Engineering, 2013
- Magnetorheological Fluid Technology2012
- Study on the usability evaluation of prosthetic leg products based on ergonomicsJournal of the Brazilian Society of Mechanical Sciences and Engineering, 2011
- The knee joint design and control of above-knee intelligent bionic leg based on magneto-rheological damperInternational Journal of Automation and Computing, 2010
- A geometrical optimization of a magneto-rheological rotary brake in a prosthetic kneeSmart Materials and Structures, 2010
- The application research of MR damper in intelligent bionic leg2009
- User‐adaptive control of a magnetorheological prosthetic kneeIndustrial Robot: the international journal of robotics research and application, 2003
- Bioengineering. Effects of Knee and Ankle Movements on Foot Impact Forces in Human Walking.JSME International Journal Series C, 2001
- Corrective reactions to stumbling in man: neuronal co‐ordination of bilateral leg muscle activity during gait.The Journal of Physiology, 1984