Influence of scan mode (180°/360°) of the cone beam computed tomography for preoperative dental implant measurements
- 12 December 2012
- journal article
- research article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 25 (2) , e155-e158
Abstract
Objective The aim of this study was to evaluate the effect of scan mode of the cone beam computed tomography (CBCT) in the preoperative dental implant measurements. Material and methods Completely edentulous mandibles with entirely resorbed alveolar processes were selected for this study. Five regions were selected (incisor, canine, premolar, first molar, and second molar). The mandibles were scanned with Next Generation i‐CAT CBCT unit (Imaging Sciences International, Inc, Hatfield, PA, USA) with half (180°) and full (360°) mode. Two oral radiologists performed vertical measurements in all selected regions; the measurements of half of the sample were repeated within an interval of 30 days. The mandibles were sectioned using an electrical saw in all evaluated regions to obtain the gold standard. The intraclass correlation coefficient was calculated for the intra‐ and interobserver agreement. Descriptive statistics were calculated as mean, median, and standard deviation. Wilcoxon signed rank test was used to determine the correlation between the measurements obtained in different scan mode with the gold standard. The significance level was 5%. Results The values of intra‐ and interobserver reproducibility indicated a strong agreement. In the dental implant measurements, except the bone height of the second molar region in full scan mode (P = 0.02), the Wilcoxon signed rank test did not show statistical significant difference with the gold standard (P > 0.05). Conclusions Both modes provided real measures, necessary when performing implant planning; however, half scan mode uses smaller doses, following the principle of effectiveness. We believe that this method should be used because of the best dose–effect relationship and offer less risk to the patient.Keywords
This publication has 15 references indexed in Scilit:
- Effect of electric potential and current on mandibular linear measurements in cone beam CTDentomaxillofacial Radiology, 2012
- Optimization of cone beam CT exposure for pre-surgical evaluation of the implant siteDentomaxillofacial Radiology, 2012
- Evaluation of subjective image quality in relation to diagnostic task for cone beam computed tomography with different fields of viewEuropean Journal of Radiology, 2011
- Diagnostic accuracy of limited‐volume cone‐beam computed tomography in the detection of periapical bone loss: 360° scans versus 180° scansInternational Endodontic Journal, 2011
- Diagnostic accuracy of small volume cone beam computed tomography and intraoral periapical radiography for the detection of simulated external inflammatory root resorptionInternational Endodontic Journal, 2010
- Cone‐Beam CT for Preoperative Implant Planning in the Posterior Mandible: Visibility of Anatomic LandmarksClinical Implant Dentistry and Related Research, 2009
- Conebeam CT of the Head and Neck, Part 1: Physical PrinciplesAmerican Journal of Neuroradiology, 2009
- Image qualityvsradiation dose of four cone beam computed tomography scannersDentomaxillofacial Radiology, 2008
- Computed tomography for dental implants: the influence of the gantry angle and mandibular positioning on the bone height and widthDentomaxillofacial Radiology, 2005
- Measurements of distances related to the mandibular canal in radiographsClinical Oral Implants Research, 1995