Expert consensus document on the assessment of the severity of aortic valve stenosis by echocardiography to provide diagnostic conclusiveness by standardized verifiable documentation
- 3 September 2019
- journal article
- review article
- Published by Springer Nature in Clinical Research in Cardiology
- Vol. 109 (3) , 271-288
Abstract
According to recent recommendations on echocardiographic assessment of aortic valve stenosis direct measurement of transvalvular peak jet velocity, calculation of transvalvular mean gradient from the velocities using the Bernoulli equation and calculation of the effective aortic valve area by continuity equation are the appropriate primary key instruments for grading severity of aortic valve stenosis. It is obvious that no gold standard can be declared for grading the severity of aortic stenosis. Thus, conclusions of the exclusive evaluation of aortic stenosis by Doppler echocardiography seem to be questionable due to the susceptibility to errors caused by methodological limitations, mathematical simplifications and inappropriate documentation. The present paper will address practical issues of echocardiographic documentation to satisfy the needs to analyze different scenarios of aortic stenosis due to various flow conditions and pressure gradients. Transesophageal and multidimensional echocardiography should be implemented for reliable measurement of geometric aortic valve area and of cardiac dimensions at an early stage of the diagnostic procedure to avoid misinterpretation due to inconsistent results.Keywords
This publication has 63 references indexed in Scilit:
- The anatomy of the aortic rootClinical Anatomy, 2013
- Inconsistent echocardiographic grading of aortic stenosis: is the left ventricular outflow tract important?Heart, 2013
- Low-Gradient Aortic Valve StenosisJACC, 2011
- Comparison of two-dimensional and three-dimensional imaging techniques for measurement of aortic annulus diameters before transcatheter aortic valve implantationHeart, 2011
- Impact of pulmonary hypertension on outcomes after aortic valve replacement for aortic valve stenosisThe Journal of Thoracic and Cardiovascular Surgery, 2011
- Paradoxical low flow and/or low gradient severe aortic stenosis despite preserved left ventricular ejection fraction: implications for diagnosis and treatmentEuropean Heart Journal, 2009
- Assessing aortic valve area in aortic stenosis by continuity equation: a novel approach using real-time three-dimensional echocardiographyEuropean Heart Journal, 2008
- Impact of blood pressure on the Doppler echocardiographic assessment of severity of aortic stenosisHeart, 2006
- Left atrioventricular plane displacement but not left ventricular ejection fraction is influenced by the degree of aortic stenosisHeart, 2004
- A practical application of Doppler echocardiography for the assessment of severity of aortic stenosisAmerican Heart Journal, 1988