Digital Chest Radiography with a Selenium-Based Flat-Panel Detector Versus a Storage Phosphor System
Authors:
- 1 October 2000
- journal article
- research article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 175 (4) , 1013-1018
Abstract
OBJECTIVE. We compared the soft-copy images produced by a digital chest radiography system that uses a flat-panel X-ray detector based on amorphous selenium with images produced by a storage phosphor radiography system for the visualization of anatomic regions of the chest.MATERIALS AND METHODS. Two chest radiologists and two residents analyzed 46 pairs of posteroanterior chest radiographs on high-resolution video monitors (2560 × 2048 × 8 bits). In each pair, one radiograph was obtained with a storage phosphor radiography system, and the other radiograph was obtained with a selenium-based flat-panel detector radiography system. Each pair of radiographs was obtained at the same exposure settings. The interpreter rated the visibility and radiographic quality of 11 different anatomic regions. Each pair of images was ranked on a five-point scale (1 = prefer image A, 3 = no preference, 5 = prefer image B) for preference of technique. Statistical significance of preference was determined using the Wilcoxon's s...Keywords
This publication has 29 references indexed in Scilit:
- Principles of Digital Radiography with Large-Area, Electronically Readable Detectors: A Review of the BasicsRadiology, 1999
- Selenium-based digital radiography versus conventional film-screen radiography of the hands and feet: a subjective comparison.American Journal of Roentgenology, 1999
- Selenium-based digital radiography of the chest: radiologists' preference compared with film-screen radiographs.American Journal of Roentgenology, 1995
- Digital chest imaging with a selenium detector: comparison with conventional radiography for visualization of specific anatomic regions of the chest.American Journal of Roentgenology, 1995
- Technical advances in chest radiography.American Journal of Roentgenology, 1994
- Digital radiography and conventional imaging of the chest: a comparison of observer performance.American Journal of Roentgenology, 1994
- High-resolution computer display of portable, digital, chest radiographs of adults: suitability for primary interpretation.American Journal of Roentgenology, 1993
- Receiver-operating-characteristic study of chest radiographs in children: digital hard-copy film vs 2K x 2K soft-copy images.American Journal of Roentgenology, 1992
- Comparison of 2048-line digital display formats and conventional radiographs: an ROC studyAmerican Journal of Roentgenology, 1989
- Total digital radiology department: spatial resolution requirementsAmerican Journal of Roentgenology, 1987