Molecular Weight-Retention Volume Relation for Narrow and Broad Polystyrenes by Size Exclusion Chromatography Equipped With a Light Scattering Detector
Authors:
- 1 April 1998
- journal article
- research article
- Published by Taylor & Francis in Journal of Liquid Chromatography & Related Technologies
- Vol. 21 (8) , 1107-1117
Abstract
The difference of the relation of molecular weight (MW) and retention volume of narrow polystyrene (PS) samples from broad ones in the size exclusion chromatography - light scattering (LS)/refractive index (RI) detectors is discussed. Effects of interdetector delay volume on the relation was serious and the approach to adjust the interdetector delay volume so as to get a plateau relation of MW and retention volume for PS samples with a narrow MW distribution was proposed. The interdetector delay volume was found to be a function of MW. PS samples with a broad MW distribution had the similar relation of MW and retention volume to the calibration curve constructed with PS standards with narrow MW distributions; and the MW averages obtained by the LS/RI approach gave the comparable values to those calculated by a calibration curve method.Keywords
This publication has 10 references indexed in Scilit:
- Problems of Baseline Construction for Calculation of Molecular Weight Averages in Size Exclusion ChromatographyJournal of Liquid Chromatography & Related Technologies, 1996
- Measurement of narrow-distribution polydispersity using multiangle light scatteringJournal of Chromatography A, 1994
- Mean square radius of molecules and secondary instrumental broadeningJournal of Chromatography A, 1993
- Evaluation of light‐scattering detectors for size exclusion chromatography. I. Instrument precision and accuracyJournal of Applied Polymer Science, 1993
- Chemometrics in quantitative polymer analysis: Attempts to displace traditional methodsJournal of Applied Polymer Science, 1991
- Measurement of Interdetector Volume in Size Exclusion/Low-Angle Laser Light Scattering ExperimentsJournal of Liquid Chromatography, 1990
- Use of a Viscometric Detector for Size Exclusion Chromatography1987
- Measurement of the Dead Volume between Concurrent Detectors in Gel Permeation ChromatographyJournal of Liquid Chromatography, 1982
- Problems in Determining Compositional Heterogeneity of Copolymers by Size-Exclusion Chromatography and UV-RI Detection SystemJournal of Liquid Chromatography, 1981
- Method of calculating molecular weight distribution function from gel permeation chromatogramsJournal of Applied Polymer Science, 1966