Endovascular reconstruction of unruptured intradural vertebral artery dissecting aneurysms with the Pipeline embolization device
- 6 November 2015
- journal article
- research article
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 8 (10) , 1048-1051
Abstract
Background Dissecting aneurysms of the vertebral artery (VA) are difficult to treat using current surgical and endovascular techniques. Objective To analyze retrospectively the efficacy and safety of flow diverters in the treatment of dissecting aneurysms of the vertebral artery. Methods We identified six patients with six unruptured VA dissecting aneurysms either arising from the V4 or V3–V4 junction that were treated with the Pipeline embolization device (PED) at our institution between July 2012 and February 2015. Among other parameters, technical feasibility of the procedure, procedure-related complications, angiographic results, and clinical outcome were evaluated. Results PED placement was achieved in all cases and immediate angiography follow-up demonstrated intra-aneurysmal contrast stasis with parent artery preservation. A temporary episode of dysarthria was noted in one patient. Major procedure-related complications were not observed. The 6-month follow-up (n=6) demonstrated complete/near-complete aneurysm obliteration in five patients and partial obliteration in one. At the 1-year follow-up (n=5) stable complete aneurysm occlusion was seen in two patients. Two cases showed progression from near complete occlusion and partial occlusion at 6 months to complete occlusion and near complete occlusion. One cases showed unchanged near complete occlusion. No aneurysmal bleeding, in-stent stenosis or thromboembolic complication was seen. National Institutes of Health Stroke Scale and modified Rankin scale scores remained unchanged from admission to discharge. Conclusions Our preliminary experience with the use of PED for the treatment of intradural VA dissecting aneurysms shows promising short-term results, making this technique a feasible and safe treatment option in patients suitable for this approach. However, long-term and larger cohort studies are needed to validate these results.Keywords
This publication has 18 references indexed in Scilit:
- Simple Measurement of Aneurysm Residual after Treatment: the SMART scale for evaluation of intracranial aneurysms treated with flow divertersActa Neurochirurgica, 2011
- The Role of the Pipeline Embolization Device for the Treatment of Dissecting Intracranial AneurysmsAmerican Journal of Neuroradiology, 2011
- Assessment of angiographic outcomes after flow diversion treatment of intracranial aneurysms: a new grading schemaNeuroradiology, 2010
- Endovascular treatment of ruptured dissecting vertebral artery aneurysms—long-term follow-up results, benefits of early embolization, and predictors of outcomeActa Neurochirurgica, 2010
- Stent-assisted coil embolization followed by a stent-within-a-stent technique for ruptured dissecting aneurysms of the intracranial vertebrobasilar arteryJournal of Neurosurgery, 2009
- Endovascular Strategies for Vertebrobasilar Dissecting AneurysmsAmerican Journal of Neuroradiology, 2009
- Clinical and Angiographic Follow-Up of Stent-Only Therapy for Acute Intracranial Vertebrobasilar Dissecting AneurysmsAmerican Journal of Neuroradiology, 2009
- Application of covered stent grafts for intracranial vertebral artery dissecting aneurysmsJournal of Neurosurgery, 2009
- Dissecting vertebral artery aneurysm: diagnosis and coil embolization.British Journal of Radiology, 1999
- Clinical Analysis of a Series of Vertebral Aneurysm CasesNeurosurgery, 1992