Abstract
A scattering-scanning near-field microscope, integrated with a 100 GHz zero-intermediate frequency radar system, is proposed and demonstrated. Near-field imaging with a resolution of 140 nm is achieved through the utilization of a fundamental mixer. The non-focusing structure simplifies the original focusing optical path and, combined with single-source zero intermediate frequency radar technology, streamlines the overall system structure while ensuring data collection efficiency. This facilitates subsequent system integration. The impacts on the actual excitation and collection of near-field signals were compared between the focusing mode and the non-focusing mode. Subsequently, near-field imaging in the non-focusing mode was successfully accomplished. A signal-to-noise ratio of 35 dB in near-field amplitude images is attained by using commercial probes. This indicate that the unique system structure can provide a new solution for low-terahertz bans scanning near-field microscopes.
Funding Information
  • Youth Innovation Promotion Association Chinese Academy of Sciences (E1213A041S)