The hemodynamic cardiac profiler volume-time curves and related parameters: an MRI validation study
Open Access
- 1 January 2024
- journal article
- research article
- Published by IOP Publishing in Physiological Measurement
- Vol. 45 (1) , 01NT01
Abstract
Background. The hemodynamic cardiac profiler (HCP) is a new, non-invasive, operator-independent screening tool that uses six independent electrode pairs on the frontal thoracic skin, and a low-intensity, patient-safe, high-frequency applied alternating current to measure ventricular volume dynamics during the cardiac cycle for producing ventricular volume-time curves (VTCs). Objective. To validate VTCs from HCP against VTCs from MRI in healthy volunteers. Approach. Left- and right-ventricular VTCs were obtained by HCP and MRI in six healthy participants in supine position. Since HCP is not compatible with MRI, HCP measurements were performed within 20 min before and immediately after MRI, without intermittent fluid intake or release by participants. Intraclass correlation coefficients (ICCs) were calculated to validate HCP-VTC against MRI-VTC and to assess repeatability of HCP measurements before and after MRI. Bland–Altman plots were used to assess agreement between relevant HCP- and MRI-VTC-derived parameters. Precision of HCP’s measurement of VTC-derived parameters was determined for each study participant by calculating the coefficients of variation and repeatability coefficients. Main results. Left- and right-ventricular VTC ICCs between HCP and MRI were >0.8 for all study participants, indicating excellent agreement between HCP-VTCs and MRI-VTCs. Mean (range) ICC of HCP right-ventricular VTC versus MRI right-ventricular VTC was 0.94 (0.88–0.99) and seemed to be slightly higher than the mean ICC of HCP left-ventricular VTC versus MRI-VTC (0.91 (0.80–0.96)). The repeatability coefficient for HCP’s measurement of systolic time (tSys) was 45.0 ms at a mean value of 282.9 ± 26.3 ms. Repeatability of biventricular HCP-VTCs was excellent (ICC 0.96 (0.907–0.995)). Significance. Ventricular volume dynamics measured by HCP-VTCs show excellent agreement with VTCs measured by MRI. Since abnormal tSys is a sign of numerous cardiac diseases, the HCP may potentially be used as a diagnostic screening tool.Keywords
This publication has 26 references indexed in Scilit:
- Cardiovascular magnetic resonance for the diagnosis and management of heart failure with preserved ejection fractionHeart Failure Reviews, 2020
- Association Between Systolic Ejection Time and Outcomes in Heart Failure by Ejection FractionEuropean Journal of Heart Failure, 2019
- A Practical Guide to Assess the Reproducibility of Echocardiographic MeasurementsJournal of the American Society of Echocardiography, 2019
- Reproducibility of peak filling and peak emptying rate determined by cardiovascular magnetic resonance imaging for assessment of biventricular systolic and diastolic dysfunction in patients with pulmonary arterial hypertensionThe International Journal of Cardiovascular Imaging, 2017
- Non-invasive measurement of volume–time curves in patients with mitral regurgitation and in healthy volunteers, using a new operator-independent screening toolPhysiological Measurement, 2017
- Right Ventricular Function in Left Ventricular Disease: Pathophysiology and ImplicationsHeart, Lung and Circulation, 2013
- Invasive Hemodynamic Assessment in Heart FailureHeart Failure Clinics, 2009
- Clinical significance of diastolic function as an indicator of myocardial ischemia assessed by 16-frame gated myocardial perfusion SPECTAnnals of Nuclear Medicine, 2008
- Cardiovascular magnetic resonance imaging: Current and emerging applicationsJACC, 2004
- Cardiotoxicity of cytotoxic drugsCancer Treatment Reviews, 2004