Purpose.: This study investigated the protein deposition that occurs on daily wear silicone hydrogel (SH) lenses, after 2 weeks of wear. Methods.: A total of 40 subjects were divided into equal groups, based on their habitual SH contact lens [CIBA Vision O 2 OPTIX (O2); Johnson & Johnson ACUVUE ADVANCE with HYDRACLEAR (ADV); Bausch & Lomb PureVision (PV); CIBA Vision Night & Day (ND)]. A randomized, double‐masked, cross‐over study was conducted in which subjects wore either their habitual SH material or Johnson & Johnson ACUVUE OASYS with HYDRACLEAR PLUS (OAS) for 2 weeks. At the end of the 2‐week period, lenses were collected for analysis of total protein, total lysozyme, and percent denatured lysozyme. Results.: Total protein was greatest for PV (33 ± 6 μg/lens), with other lenses depositing 0.05). Total lysozyme was also greatest for the PV lens (11 ± 3 μg/lens), with other lenses depositing 0.05). The percentage of lysozyme that was denatured was greatest for ND (90 ± 8%) and lowest for PV (23 ± 10%). The lysozyme extracted from ND and O2 lenses was significantly more denatured than that extracted from the other lens materials (p < 0.001). There were no significant differences for lysozyme activity between ND and O2 (p > 0.05) or between ADV, OAS, and PV (p > 0.05). The amount of denatured lysozyme/lens was <3 μg/lens for all materials. Lysozyme as a percentage of the total protein deposited ranged from 32 (PV) to 6% (O2). Conclusions.: This study confirms that all SH lenses deposit low levels of protein, and that the amount and percentage of denatured lysozyme can vary, depending on the overall surface charge of the material and absence or type of surface treatment.Keywords
This publication has 57 references indexed in Scilit:
- A Seven Year Survey of the Contact Lens Prescribing Habits of Canadian OptometristsOptometry and Vision Science, 2007
- Oxygen Permeability and Water Content of Silicone Hydrogel Contact Lens MaterialsOptometry and Vision Science, 2007
- Frequency of and Factors Associated With Contact Lens Dissatisfaction and DiscontinuationCornea, 2007
- A market survey of contact lens practice in Hong KongClinical and Experimental Optometry, 2005
- A multi‐centre study of lapsed contact lens wearersOphthalmic and Physiological Optics, 2002
- Characterization of Ocular Surface Symptoms From Optometric Practices in North AmericaCornea, 2001
- Vascular Response to Extended Wear of Hydrogel Lenses with High and Low Oxygen PermeabilityOptometry and Vision Science, 2001
- Microcyst Response to High Dk/t Silicone Hydrogel Contact LensesOptometry and Vision Science, 2000
- Discontinuation of contact lens wear: a surveyInternational Contact Lens Clinic, 1999
- On the Relationship Between Soft Contact Lens Oxygen Transmissibility and Induced Limbal HyperaemiaExperimental Eye Research, 1998