Assessing dosimetric uncertainties in Papillon+ contact x-ray brachytherapy for rectal cancer: impact of beam quality and tumour geometry
Authors:
- Dries ColsonDCDries Colson
- Femke VaassenFVFemke Vaassen
- Burak YalvacBYBurak Yalvac
- Jan WeteringsJWJan Weterings
- van Haaren PaulVPvan Haaren Paul
- An-Sofie VerrijssenAVAn-Sofie Verrijssen
- Maaike BerbéeMBMaaike Berbée
- Evert J Van LimbergenELEvert J Van Limbergen
- Murillo BellezzoMBMurillo Bellezzo
- Frank VerhaegenFVFrank Verhaegen
- Brigitte ReniersBRBrigitte Reniers
- 17 April 2026
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (8) , 085007
Abstract
Objective. To investigate the evolution of beam quality in the Papillon+ contact x-ray therapy device and its dosimetric impact, a fast and straightforward beam quality index (QI) measurement method was proposed and validated. Additionally, the dosimetric consequences of tumour intrusion into the applicator tube were examined through Monte Carlo (MC) simulations and, for the first time, direct in-applicator dose measurements. Approach. QI measurements were performed every four weeks from mid-2022. Half-value layer (HVL) and depth-dose profile measurements in a plastic water low energy range phantom were conducted twice, with a two-year interval. Dose distributions for tumour intrusion scenarios (2.5–10 mm) were assessed using MC simulations and Gafchromic film measurements inside the applicator tube. Gross tumour volume (GTV) dose calculations (physical and EQD2) were performed for varying tumour thicknesses, intrusion depths, and diameters. Main results. All methods consistently demonstrated progressive beam hardening over time, with the HVL increasing from 0.77 mm Al to 0.93 mm Al. This spectral shift, attributed to x-ray tube ageing and radiation-induced material changes, was reversibly corrected after service replacement of the flattening filter, restoring the soft spectrum (HVL ≈ 0.69 mm Al). Tumour intrusion produced the strongest dosimetric effect, with surface dose increases up to 2.4-fold at 10 mm intrusion, exceeding MC predictions. GTV D90 decreased with tumour thickness but increased sharply with intrusion depth, whereas tumour diameter and surrounding medium had a negligible impact. Significance. This work highlights the importance of systematic beam quality follow-up in contact x-ray brachytherapy systems. Routine QI monitoring, together with well-defined beam-quality specifications and action limits, enables early detection of deviations, timely maintenance, and sustained compliance of the delivered beam quality in clinical practice. Tumour positioning relative to and protrusion into the applicator remains the dominant factor affecting dose distribution, underscoring the need for precise clinical setup and ongoing device characterisation to ensure clinical accuracy and patient safety.Keywords
Funding Information
- Bijzonder Onderzoeksfonds UGent (BOF19DOC28)
- Research Foundation - Flanders (FWO) and Flemisch Government
- Horizon 2020 Research and Innovation Programme (18NRM02)
This publication has 27 references indexed in Scilit:
- Microscopic intramural spread in patients with rectal cancer after neoadjuvant chemoradiationClinical and Translational Radiation Oncology, 2025
- A phase III randomised trial on the addition of a contact X-ray brachytherapy boost to standard neoadjuvant chemo-radiotherapy for organ preservation in early rectal adenocarcinoma: 5 year results of the OPERA trialAnnals of Oncology, 2024
- Dosimetry and Monte Carlo modelling of the Papillon+ contact X-ray brachytherapy deviceBrachytherapy, 2024
- Online MR guided dose escalated radiotherapy for organ preservation in distal rectal cancerClinical and Translational Radiation Oncology, 2022
- Endorectal contact radiation boosting: Making the case for dose AND volume reportingBrachytherapy, 2022
- GEC ESTRO ACROP consensus recommendations for contact brachytherapy for rectal cancerClinical and Translational Radiation Oncology, 2021
- Contact X-ray brachytherapy for rectal cancer: Past, present, and futureCancer/Radiothérapie, 2021
- The TOPAS tool for particle simulation, a Monte Carlo simulation tool for physics, biology and clinical researchPhysica Medica, 2020
- The influence of local tumor ulceration on the effectiveness of endocavitary radiation for patients with early rectal carcinomaCancer, 1995
- PENELOPE: An algorithm for Monte Carlo simulation of the penetration and energy loss of electrons and positrons in matterNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1995