Lateral Impact Response of Rubberized-Fibrous Concrete-Filled Steel Tubular Columns: Experiment and Numerical Study
Open Access
- 29 September 2022
- Vol. 12 (10) , 1566
Abstract
This paper presents an experimental and numerical study on the lateral impact behavior of rubberized-fibrous concrete-filled steel tubular (CFST) columns. Four types of concrete were utilized in the experimental program in the infilled columns: normal concrete (NC), rubberized concrete (RuC), steel fiber concrete (SFC), and hybrid RuC-SFC. Twelve specimens were tested using drop-weight impact with fixed-sliding boundary conditions. Three different transverse impact energies were produced by applying two masses of the hammers dropped from two different heights. A high-speed camera was implemented to measure the mid-span deflection against time. A 3-D finite element model was presented and verified against the tested specimens and some other experimental work from the literature. Load-displacement curves, the impact force time history, impact energy absorption, and failure modes of the CFST columns under the lateral impact were fully analyzed. The present results showed that at, certain impact energies, the steel tubular suffered only from the plastic deformation, beyond which it started cracking depending on the type of filled concrete. The steel tubular filled with hybrid RuC-SFC showed the highest resistance to crack formation, followed by that filled with SFC, while those filled with NC showed the lowest resistance to crack formation. There is an agreement between the numerical and the experimental results.Keywords
This publication has 45 references indexed in Scilit:
- Effects of rubber aggregates from grinded used tyres on the concrete resistance to crackingJournal of Cleaner Production, 2012
- Design of hollow and concrete filled steel and stainless steel tubular columns for transverse impact loadsThin-Walled Structures, 2011
- Analysis of Circular Concrete-Filled Steel Tube Specimen under Lateral ImpactAdvances in Structural Engineering, 2011
- Behaviour of recycled aggregate concrete under drop weight impact loadConstruction and Building Materials, 2011
- An experimental study on the tensile strength of steel fiber reinforced concreteComposites Part B: Engineering, 2010
- Mechanical properties of concrete containing a high volume of tire–rubber particlesWaste Management, 2008
- Tests on impact behaviour of micro-concrete-filled steel tubes at elevated temperatures up to 400°CMaterials and Structures, 2008
- Hollow and concrete filled steel hollow sections under transverse impact loadsEngineering Structures, 2008
- Mechanical properties of high-strength steel fiber-reinforced concreteConstruction and Building Materials, 2004
- The properties of rubberized concretesCement and Concrete Research, 1995