Incidence of Antitachycardia Therapy Suspension Due to Magnet Reversion in Implantable Cardioverter Defibrillators
- 6 February 2004
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 27 (2) , 221-223
Abstract
Electromagnetic interference may result in transient or persistent suspension of antitachycardia therapies in ICDs. The incidence of such events has not been assessed so far. Patient charts were retrospectively analyzed for the occurrence of temporary suspension of antitachycardia therapies as it is stored in the Holter of St. Jude Medical or Ventritex ICDs. Follow‐up data of 46 patients and 83.7‐patient years were analyzed. Overall, 43 episodes of transient ICD inactivation occurred. Twenty‐two of these episodes were related to intentional ICD inactivation in the emergency room or during surgery and 12 episodes were related to ICD follow‐up. In nine episodes an environmental source of electromagnetic interference is presumed. None of the interactions resulted in persistent ICD inactivation or reprogramming of the devices. The risk for temporary suspension of ICD therapies unrelated to surgery, intentional magnet application in the emergency room, or routine follow‐up is 11% per patient and year. Evaluation of its potential sources and the prevalence of ICD inhibition is warranted. (PACE 2004; 27:221–223)Keywords
This publication has 10 references indexed in Scilit:
- Do airport metal detectors interfere with implantable pacemakers or cardioverter-defibrillators?JACC, 2003
- Interference in Implanted Cardiac Devices, Part IPacing and Clinical Electrophysiology, 2002
- Unintentional Deactivation of Implantable Cardioverter-Defibrillators in Health Care SettingsMayo Clinic Proceedings, 2002
- Incidence of Electromagnetic Interference in Implantable Cardioverter DefibrillatorsPacing and Clinical Electrophysiology, 2001
- Interactions Between Electronic Article Surveillance Systems and Implantable Cardioverter-DefibrillatorsCirculation, 1999
- Digital Cellular Telephone Interaction With Implantable Cardioverter-DefibrillatorsJACC, 1998
- Implantable Cardioverter Defibrillator: Possible Hazards of Electromagnetic InterferencePacing and Clinical Electrophysiology, 1991
- Inadvertent AICD inactivation while playing bingoAmerican Heart Journal, 1991
- Accidental deactivation of the automatic implantable cardioverter defibrillatorAmerican Heart Journal, 1990
- Stereo Speaker Silences Automatic Implantable Cardioverter–DefibrillatorNew England Journal of Medicine, 1989