Background— Complete supraannular placement of an aortic bioprosthesis is one approach to optimize the hemodynamic result of an aortic valve replacement. It is achieved with the combination of a special valve design and the supraannular sewing technique with noneverted mattress sutures. We evaluated 5 bioprostheses designed for complete supraannular placement to assess potential hemodynamic differences caused by factors (eg, valve material) other than implantation position. Methods and Results— In 336 patients (mean age, 72.0±7.1 years; 143 women), hemodynamics including mean pressure gradients, effective orifice areas, and indices and incidence of patient-prosthesis mismatch were evaluated 6 months after surgery. Annulus diameter was measured during surgery. Patients received the Carpentier Edwards Perimount Magna (Magna, n=169), the Medtronic Mosaic (Mosaic, n=46), the Mosaic Ultra (Ultra, n=17), the SJM Epic Supra (Epic, n=46), and the Sorin Soprano (Soprano, n=58). For small annulus sizes (24 mm) annulus sizes, the mean pressure gradients of the Magna were lower than the Epic (10.0±3.5 mm Hg versus 14.9±6.4 mm Hg; 9.9±4.0 mm Hg versus 18.6±12.7 mm Hg). Furthermore, in patients with large annulus size, the mean pressure gradients of the Soprano (11.4±3.8 mm Hg) were lower compared with the Epic (18.5±12.7 mm Hg). Severe patient-prosthesis mismatch was observed more frequently in patients with the Mosaic (12/46; 26.1%) and the Ultra (3/17; 17.6%) prostheses. Conclusions— Complete supraannular placement cannot prevent high pressure gradients or patient-prosthesis mismatch thoroughly, but the choice of a bovine prosthesis can optimize hemodynamic performance.Keywords
This publication has 27 references indexed in Scilit:
- The changing spectrum of bioprostheses hydrodynamic performance: considerations on in-vitro testsInteractive CardioVascular and Thoracic Surgery, 2008
- Twenty-Year Experience With the St. Jude Medical Biocor Bioprosthesis in the Aortic PositionThe Annals of Thoracic Surgery, 2008
- Opening and closing kinematics of fresh and calcified aortic valve prostheses: An in vitro studyThe Journal of Thoracic and Cardiovascular Surgery, 2007
- Carpentier-Edwards Perimount Magna Valve Versus Medtronic Hancock II: A Matched Hemodynamic ComparisonThe Annals of Thoracic Surgery, 2007
- Influence of completely supra-annular placement of bioprostheses on exercise hemodynamics in patients with a small aortic annulusThe Journal of Thoracic and Cardiovascular Surgery, 2007
- One year hemodynamic performance of the Perimount Magna pericardial xenograft and the Medtronic Mosaic bioprosthesis in the aortic position: a prospective randomized studyInteractive CardioVascular and Thoracic Surgery, 2007
- Small aortic annulus: The hydrodynamic performances of 5 commercially available tissue valvesThe Journal of Thoracic and Cardiovascular Surgery, 2006
- Hemodynamic Comparison of Bioprostheses for Complete Supra-Annular Position in Patients With Small Aortic AnnulusJACC, 2005
- Exercise hemodynamics of bovine versus porcine bioprostheses: A prospective randomized comparison of the mosaic and perimount aortic valvesThe Journal of Thoracic and Cardiovascular Surgery, 2005
- European experience with the Mosaic bioprosthesisThe Journal of Thoracic and Cardiovascular Surgery, 2002